AIX 更换 RAID 5 阵列中的故障硬盘

IBM 小型机更换硬盘过程: raid5

一、 现象描述

一台IBM小型机,带RAID卡,内置3块硬盘,做RAID5,无热备

第2块硬盘亮黄色故障灯

二、 做好rootvg备份(mksysb)和数据备份(强烈建议)

备份完数据后,为了安全,停止应用对硬盘的访问

三、 故障确认

执行lsdev –Cc pdisk/hdisk、errpt命令查看系统是否有硬盘报错

 用diag->Task selection -> RAID Array Manager ->       

IBM SASDisk Array Manager ->List IBM SASDisk Array configuration检查raid信息和pdisk 的状态

hdisk0    0B-08-ff-0,0  Degraded    RAID 5 Array     484.2GB     

pdisk0   0B-08-00-5,0  Failed      Array Member     242.8GB       

pdisk1   0B-08-01-5,0  Active      Array Member     242.8GB     

pdisk2   0B-08-00-3,0  Active      Array Member     242.8GB

用以下操作再次确认硬盘槽位信息:

Diag->Task Selection->RAID Array Manager->IBM SASDisk Array Manager-> Diagnostics and Recovery Options->SCSI and SCSI RAID Hot Plug Manager-> Identify a Device Attached to a SCSI Hot Swap Enclosure Device    

选择对应的硬盘,按F7确认硬盘所在的槽位(磁盘的黄灯在闪烁)

四、 进行磁盘更换

1)     用hot plug把硬盘更换,操作如下:

diag?    

Task Selection?    

RAID Array Manager?     

IBM SASDisk Array Manager?    

   Diagnostics and Recovery Options?     

         SCSI and SCSI RAID Hot Plug Manager?     

Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device    

把故障硬盘更换,回车

然后按F3回到上一层菜单

       SCSI and SCSI RAID Hot Plug Manager     

         Configure Added/Replaced Devices     

2)     更换硬盘后,回到

diag->    

Task selection ->     

         RAID Array Manager ->      

IBM SASDisk Array Manager ->    

        List IBM SAS Disk Array configuration     

可以看到pdiskX的状态是failed,比如下图:

3)   hdisk0    0B-08-ff-0,0  Degraded    RAID 5 Array     484.2GB     

   pdisk0   0B-08-00-5,0  Failed      Array Member     242.8GB       

   pdisk1   0B-08-01-5,0  Active      Array Member     242.8GB     

   pdisk2   0B-08-00-3,0  Active      Array Member     242.8GB     

7)     用lsdev –Cc pdisk是可以看到pdisk0是available    

五、 对RAID进行重建

diag->    

Task selection ->     

       RAID Array Manager ->      

IBM SASDisk Array Manager ->    

           Reconstruct a IBM SASDisk Array     

选择新产生的磁盘pdisk0进行重建(对146GB HDD大概需要4小时)      

重建有进度显示,可以退出重建在后台执行

六、 重建完毕后,确认RAID的状态为optimal

diag->    

Task selection ->     

          RAID Array Manager ->      

IBM SASDisk Array Manager ->    

       List IBM SASDisk Array configuration     

七、 确认硬盘没问题,启动应用

2 次浏览 更新于 2026-11-04

同组文章Power / AIX

查看本组全部 18 篇

没有找到想要的答案?