EMC VMAX 定位故障硬盘物理位置
EMC VMAX– IDENTIFY FAILED DRIVE LOCATION
https://blog.csdn.net/weixin_30911809/article/details/102243288
In order to understand this Post fully, I would advise you read “EMC VMAX – 20/40K Back-End Connectivity” first.
Having completed a VMAX ‘Health Check’ through ‘Unisphere’ it has been highlighted that a drive has failed:

Running the command symdisk list -failed will display the details of the failed disk (-v for more detail):

You can also check if the failed disk has been spared out by issuing the command symdisk list -isspare:


‘Ident/Symb’ = ‘9B’ identifies the Director and the MOD that the drive is connected to at the Back-End. Thus we can gather at this stage that the drive is connected to Director 9 (Engine5).
On both directors of Engine5(9&10) there are two Back-End IO modules (MOD0 & MOD1) per director, MOD0 has connections A0,A1,B0,B1 and MOD1 has connections C0,C1,D0,D1. MOD0 on both the even and odd directors connect to DAE’s 9,13,10,14 with MOD1 on both directors connecting to DAE’s 11,15,12,16. The 8 Redundant Loops on Engine5 connect up as follows:
DAE9=LOOP0 (A0)
DAE10=LOOP2 (B0)
DAE11=LOOP4 (C0)
DAE12=LOOP6 (D0)
DAE13=LOOP1 (A1)
DAE14=LOOP3 (B1)
DAE15=LOOP5 (C1)
DAE16=LOOP7 (D1)
C = Port 0
D = Port 1
Thus far we can determine that the Drive is located on LOOP2 (9B 0).

TID’ = ‘1’ refers to the target ID, or the disk location on the Loop.
From all this information we can determine that the location of the Failed drive (‘9B 0 1’) is ‘Drive Bay-1A, DAE-10, Disk-01’:

If you have access to SymmWin then you can Toggle the disk LED:

https://davidring.ie/2013/12/12/emc-vmax-2040k-back-end-connectivity/
EMC VMAX – 20/40K BACK-END CONNECTIVITY
Each Engine has two Directors with each Director containing two Back-End Fibre Channel I/O Modules (Labeled MOD0 & MOD1). These modules (also known as DA’s – Disk Adapters) provide Fibre Channel Connectivity to the drives. As you can see from the image below there is just a single physical port on the Back-end IO Module, this single port is a Quad SFP port (QSFP). The connecting cable has a single copper QSFP transceiver connector consisting of 4 Fibre channel cables aggregated into one Single QSFP port. While at the Drive Bay side the 4 Fibre channel cables branch out as individual connections to the link control cards (LCC) as we will see shortly. Each DAE contains two LCC cards (LCCA & LCCB).


Here is an example of a Standard VMAX Storage Bay Configuration fully populated (8 Engines) with 10 storage BAYS as if viewed from the Front of the VMAX. In this fully populated configuration you have four direct connect storage bays (Bay 1’s) and six daisy chained Storage Bays (2’s & 3’s). Each octant represents connectivity from a Single Engine (2 x Directors).




Checking the connectivity on DAE 1 you can see MOD0 from the Even Director (Dir8) connects to the primary port on LCCB and MOD0 from the Odd Director (Dir7) connects to the primary port on LCCA. Note that all connections from the Even Directors connect to LCCB and all the Odd directors connect to the LCCA cards. On the loop configuration you can see that DAE1 is on Loop0. There are 8 Redundant Loops in total from the Engine:
DAE1=LOOP0 (A0(P1))
DAE2=LOOP2 (B0(P3))
DAE3=LOOP4 (C0(P1))
DAE4=LOOP6 (D0(P3))
DAE5=LOOP1 (A1(P2))
DAE6=LOOP3 (B1(P4))
DAE7=LOOP5 (C1(P2))
DAE8=LOOP7 (D1(P4))

Here is the full connectivity map for Engine 4: Also note the following translations for MOD0 A0=P1 A1=P2 B0=P3 B1=P4 and likewise for MOD1 C0=P1 C1=P2 D0=P3 D1=P4

This completes the example of the direct attach Back-end cabling for Engine 4. The same rules apply as you add more engines. As a result of this design the back-end cabling provides dual access across directors to each drive eliminating any single point of failure (8 Redundant Loops).
To Summarize:
• 8 Redundant Loops – A0,A1,B0,B1,C0,C1,D0,D1
• LCCA Connects to the ODD number Director
• LCCB Connects to the EVEN number Director
• Each Engine supports a seperate octant
• Each Slic (MOD) has 4x4Gig FC Links (16 Backend FC Links Per Engine)

Note: Please reference EMC Documentation for more detailed information specific to your configuration. Depending on Engine counts and Direct/Daisy configurations your cabling may expand differently.