EMC VMAX 后端连接(Backend Connectivity)
← EMC VMAX – Build Location and Model Type
EMC UIM/P – Symmetrix Discovery (Verify SYMAPI Certificates) →
EMC VMAX – 20/40K Back-End Connectivity
Posted on December 12, 2013 by Dave Ring
Each Engine has two Directors with each Director containing two Back-End Fibre Channel I/O Modules (Labeled MOD0 & MOD1). These modules (also known as DA’s – Disk Adapters) provide Fibre Channel Connectivity to the drives. As you can see from the image below there is just a single physical port on the Back-end IO Module, this single port is a Quad SFP port (QSFP). The connecting cable has a single copper QSFP transceiver connector consisting of 4 Fibre channel cables aggregated into one Single QSFP port. While at the Drive Bay side the 4 Fibre channel cables branch out as individual connections to the link control cards (LCC) as we will see shortly. Each DAE contains two LCC cards (LCCA & LCCB).


Here is an example of a Standard VMAX Storage Bay Configuration fully populated (8 Engines) with 10 storage BAYS as if viewed from the Front of the VMAX. In this fully populated configuration you have four direct connect storage bays (Bay 1’s) and six daisy chained Storage Bays (2’s & 3’s). Each octant represents connectivity from a Single Engine (2 x Directors).




Checking the connectivity on DAE 1 you can see MOD0 from the Even Director (Dir8) connects to the primary port on LCCB and MOD0 from the Odd Director (Dir7) connects to the primary port on LCCA. Note that all connections from the Even Directors connect to LCCB and all the Odd directors connect to the LCCA cards. On the loop configuration you can see that DAE1 is on Loop0. There are 8 Redundant Loops in total from the Engine:
DAE1=LOOP0 (A0(P1))
DAE2=LOOP2 (B0(P3))
DAE3=LOOP4 (C0(P1))
DAE4=LOOP6 (D0(P3))
DAE5=LOOP1 (A1(P2))
DAE6=LOOP3 (B1(P4))
DAE7=LOOP5 (C1(P2))
DAE8=LOOP7 (D1(P4))

Here is the full connectivity map for Engine 4: Also note the following translations for MOD0 A0=P1 A1=P2 B0=P3 B1=P4 and likewise for MOD1 C0=P1 C1=P2 D0=P3 D1=P4

This completes the example of the direct attach Back-end cabling for Engine 4. The same rules apply as you add more engines. As a result of this design the back-end cabling provides dual access across directors to each drive eliminating any single point of failure (8 Redundant Loops).
To Summarize:
• 8 Redundant Loops – A0,A1,B0,B1,C0,C1,D0,D1
• LCCA Connects to the ODD number Director
• LCCB Connects to the EVEN number Director
• Each Engines supports a seperate octant
• Each Slic (MOD) has 4x4Gig FC Links

Note: Please reference EMC Documentation for more detailed information specific to your configuration. Depending on Engine counts and Direct/Daisy configurations your cabling may expand differently.