IBM Storwize V7000 硬盘固件升级
When checking drive firmware levels only 1.Upload and run the upgrade utility in a Windows command prompt. (You need to be in the C:\Program Files\Putty or C:\Program Files (x86)\Putty folder.)
# pscp IBM2076_INSTALL_upgradetest_11.4 superuser@10.0.0.98:/home/admin/upgrade2.Having uploaded the file, now start PuTTY and SSH to your Storwize V7000. Logon and issue the following two commands. You are using SSH commands now,
# svcservicetask applysoftware -file IBM2076_INSTALL_upgradetest_11.4
# svcupgradetest -f -dUpload the drive microcode package
1. Upload the drive microcode package in a Windows command prompt.
# pscp IBM2076_DRIVE_20131022 superuser@172.16.0.235:/home/admin/upgrade1. List all the drive IDs and current firmware levels in a PuTTY session.
# svcinfo lsdrive -nohdr |while read did error use;do svcinfo lsdrive $did |while read id value;do if [[ $id == "firmware_level" ]];then echo $did" "$value;fi;done;done2. Check volume in Putty and SSH to your V7000. (If any volumes are returned, continuing with this procedure takes the volumes offline. )
# lsdependentvdisks -drive <ID>3. Update individual drives with this command
# svctask applydrivesoftware -file IBM2076_DRIVE_20131022 -type firmware -drive <ID>Confirm all drives are updated
1. List the firmware level of each drive in a PuTTY session.
# svcinfo lsdrive -nohdr |while read did error use;do svcinfo lsdrive $did |while read id value;do if [[ $id == "firmware_level" ]];then echo $did" "$value;fi;done;done2. Run the software upgrade test utility again
# svcupgradetest -f -d