IBM SVC 最佳实践(V6)

打开完整图文文档(PDF,共 63 页)

图文预览

IBM SVC 最佳实践(V6) · 第 1 页
第 1 页
IBM SVC 最佳实践(V6) · 第 2 页
第 2 页
正文文本
San Volume Controller (SVC)
 实施专家课程
 第三部分 最佳实践

云存储-存储虚拟化实施专家级课程

    © Copyright IBM Corporation 2009

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
课程内容说明

内容概述

   SVC 基本要求和限制

   SVC 连线及上架最佳实践

   SVC zone最佳实践(主机zone&存储zone)

   SVC连接后端存储最佳实践

   SVC连接XIV最佳实践

   SVC迁入步骤

   SVC EasyTier 最佳实践

   SVC 数据复制服务copy services最佳实践

   SVC Stretch Cluster最佳实践

    SVC与VMware 最佳实践

    Page 2

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC 基本要求和限制

Page 3

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

IBM SAN Volume Controller (SVC)
Implementation General Guidelines    vDisk

  1. Each SVC node contains four ports    Win2k  AIX   Linux SUN
  2. SVC nodes are deployed in pairs    Common Multi-Path Driver
  3. SANs must use supported switches
  4. Different vendor switches may not be used for
    connecting to the SVC nodes in the same fabric
  5. SVC‟s should be deployed with redundant    Host Zone
    SVC Node Pair
     fabrics. A single fabric is supported but will have
    reduced reliability    CACHE    SAN
  6. SVC nodes must connect to SAN switches.
    MDISK
     Direct connections to host or controllers are not
    supported    Storage Zone    Managed Disk Group
  7. Front-end hosts require special software to
    access both SVC and other controllers
  8.  All SVC nodes in the cluster must be able to see

    IBM    all back-end storage to be managed.
  9. SVC nodes now support mixed fabric speeds.

     Page 4

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
IBM SAN Volume Controller (SVC)
Implementation General Guidelines

    Storage Engine 336    SVC10. SVC supports up to 3 ISL hops in the fabric and this means    TotalStorage
    Node    that the server and the SVC cluster may be separated by up    TotalStorage    Storage Engine 336
    to 5 actual fibre channel links. Note SVC and Storage must    Pair 0

    TotalStorage    Storage Engine 336   be on same director.    SVC
11. Maximum hop count with Metro Mirror between SVC‟s in    TotalStorage    Storage Engine 336    Node
    different fabrics is 7, with a maximum of 3 ISL hops and a    Pair 1

    TotalStorage    Storage Engine 336   maximum of 3 local hops.    SVC
    Cluster    SVC

    TotalStorage    Storage Engine 33612. The supplied UPS signal cable is 1.8 metres long. UPS    Node
   must be in the same rack as the node.    TotalStorage    Storage Engine 336    Pair 2
13. Switch configurations must follow switch vendor rules.
    TotalStorage    Storage Engine 336    SVC
14. Zoning should NOT include front-end hosts and back-end    Node

    System x3250   storage in the same zone.    Pair 3
    Management Node
15. SVC nodes should use managed disks created from RAID
    arrays. JBODs are supported but not recommended.
16. The number of paths to a volume from a host to the nodes
    in the I/O Group that owns the volume must not exceed
    eight, even if eight is not the maximum number of paths
   supported by the multipath driver (SDD supports up to 32).
   To restrict the number of paths to a host volume, the fabrics
   must be zoned so that each host FC port is zoned to no
   more than two ports from each SVC node in the I/O Group
    that owns the volume.    UPSUPS
    PairPair

    19”19” RackRack MountedMounted

    Page 5

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC 连线及上架最佳实践

Page 6

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

连线及上架 Best Practices

   Install one node/UPS per I/O group in rack 1 and other node/UPS per
     I/O group in rack 2
    Main reason is to avoid accidental loss of access
      E.g. Shutdown node 1 for maintenance and accidentally pull node 2 power cord
    - I/O Group goes offline, VDisks go offline, applications go offline
     Consider not setting racks side by side to avoid localized disaster
    Nodes must be roughly within 100 meters of each other
      Except for split I/O groups
   Utilize the Redundant AC Power Switch – FC8300
     Provides dual input power to each SVC UPS thus power redundancy to
    node
     Helps improve resilience and thus SVC cluster availability
    SVC cluster not interrupted if one circuit breaker or power grid is
    unavailable

     Page 7

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Page 8

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC zone最佳实践

Page 9

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    IBM_2145:admin> svcinfo lsnode 1
  Back panel of SVC node:    id 1
   Ports Physically    name node1
    Fabric A    Fabric B
 Numbered 1-4 Left    UPS_serial_number 10L3BMQ
    to Right    WWNN 5005076801000135    3    4
    status online
    2
    1    IO_group_id 0
    IO_group_name io_grp0
8G4    4  3  1  2    partner_node_id 2
    partner_node_name node2
    4  3  1  2    config_node yes
8F4    UPS_unique_id 202378101C0D2761
    port_id 5005076801100135 (port 3)
    4   3    1   2
    port_status active8F2
    port_id 5005076801200135 (port 4)
 4F2    4    3    1    2    port_status active
    port_id 5005076801300135 (port 2)
    port_status active
    Numbers in yellow used    port_id 5005076801400135 (port 1)
    to make WWPN unique    port_status active

    Page 10

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Zoning 最佳实践

  Connect port 1 and 3 to Fabric A – WWPNs are 4 and 1
      Fabric Alias might be SVC_Node1_Even and SVC_Node1_Odd
  Connect port 2 and 4 to Fabric B – WWPNs are 3 and 2
      Fabric Alias might be SVC_Node1_Odd and SVC_Node1_Even
  Now you have an odd and even WWPN in each fabric
     Zone odd hosts with odd WWPN alias and zone even hosts with even alias on each
    fabric
  Balances workload and simplifies administration operations
      Meets SVC requirements and guidelines
      Four paths per VDisk
      Zoning of one server HBA port to one port per SVC node associated with host object

     Page 11

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Zoning 最佳实践
    Up to 4 fabrics supported using
    Zone    one port from each node
   Configuration    SVC_Cluster1
    or Zone set    Fabric B
    SVC_Cluster1
    Fabric A
    Host
    zones
    Storage Zones    Host Zones
    One per disk    One per
    Cluster Zone    subsystem    server
    Just do it!

    SVC Remote
    Non-SVC Zones    Copy Zone

    Use all SVC node ports for both host and storage I/O

     Page 12

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC-Cluster Zone1    SVC-Cluster Zone2
    (11,1;11,2;11,3;11,4)    (12,1;12,2;12,3;12,4)

    Cluster zones with
    all SVC ports

    ID    ID
    21    22

Fabric 1    Fabric 2
    0 1 2 3  4    0 1 2 3  4
    ID    ID
    11 21 13 23    12 22 14 24    11    12

    11 12 13 14    21 22 23 24
    SVC1    SVC2

 Page 13

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

     SVC-DS Zone1    SVC-DS Zone2
  (11,1;11,2;11,3;11,4;11,5)    (12,1;12,2;12,3;12,4;12,5)
    SVC-EMC Zone1    SVC-EMC Zone2
    All storage ports  (11,1;11,2;11,3;11,4;11,6)    (12,1;12,2;12,3;12,4;12,6)
    and all SVC ports
    ID    ID
    21    22

Fabric 1    Fabric 2
    0  1 2 3  4 5 6    0  1 2 3  4 5 6
    ID    ID
    11 21 13 23 D1 E1    12 22 14 24 D2 E2    11    12

    11 12 13 14   D1    D2   E1   E2    DS Family
    SVC1
    SVC    EMC
    21 22 23 24
    L x    SVC2

 Page 14

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

     SVC_AIX1-P1 Zone    AIX1    SVC_AIX1-P2 Zone
    (21,1;11,3;11,4)    P1 P2    (22,1;12,1;12,2)
    SVC_Node1_Odd;SVC    SVC_Node1_Odd;SVC
     Node2_Odd;AIX1_P1    Node2_Odd;AIX1_P2
    1    1
    ID    ID
    P1    21     P2    22

Fabric 1    Fabric 2    3  4    1 2
    ID    ID
    11 21 13 23 D1 E1    12 22 14 24 D2 E2    11    12

  AIX1 Host Port    11 12 13 14     21 22 23 24    and
    SVC1    SVC2
  One SVC Port
    Note: No storage  Per SVC Node
    subsystem ports!

 Page 15

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

     SVC_AIX2-P1 Zone    AIX2    SVC_AIX2-P2 Zone
    (21,1;11,1;11,2)    P1 P2    (22,1;12,3;12,4)
    SVC_Node1_Even;SVC    SVC_Node1_Even;SVC
    Node2_Even;AIX2_P1    Node2_Even;AIX2_P2
    1    1
    ID    ID
    P1    21     P2    22

Fabric 1    Fabric 2    1 2    3 4
    ID    ID
    11 21 13 23 D1 E1    12 22 14 24 D2 E2    11    12

  AIX2 Host Port    11 12 13 14     21 22 23 24    and
    SVC1    SVC2
  One SVC Port
    Note: No storage  Per SVC Node
    subsystem ports!

 Page 16

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC 连接后端存储

    最佳实践

Page 17

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Disk Controller Best Practices

   Multipathing from SVC to disk controller built into SVC software
   No need for Powerpath or SDD to talk to disk controllers
     Default Round-Robin Multi-pathing to External Storage System Ports after
    V6.3
  All SVC nodes must see same set of LUNs from disk controller
     Otherwise degraded mode on controller and/or MDisks
  All SVC ports zoned to controller ports must see same set of LUNs
     Otherwise degraded mode on controller and/or Mdisks
  In general configure disk systems as you would with SVC
     Disk drives
     Be careful with large disk drives you don‟t end up with too few spindles to handle load
      RAID-5 suggested, but RAID-10 is viable and useful, SVC does not negate this
    When adding more disks to a subsystem consider adding the new MDisks
    to existing MDGs versus creating additional small MDGs

     Page 18

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Disk Controller Best Practices

  Maximum of 256 WWNNs
   EMC DMX/SYMM, All HDS and SUN/HP HDS clones use one WWNN per
    port; each appears as a separate controller to SVC
      Upgrade to 4.2.1 or later so you can map LUNs thru up to 16 FA ports
    - Results in 16 WWNNs/WWPNs used out of the max of 256
    IBM, EMC Clariion, HP, etc. use one WWNN per subsystem; each
    appears as a single controller with multiple ports/WWPNs
     Maximum of 16 ports/WWPNs per WWNN using 1 out of the max of 256

     Page 19

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Disk Controller Best Practices

   If there is no plan/strategy for MDG configuration use only one
   MDG per backend disk system
   MDG RAS Considerations:
    May make sense to create multiple MDGs if you ensure a host only gets its‟ VDisks built
    from one of the MDGs
    -  If MDG goes offline then it impacts only a subset of all the hosts using SVC
    If not going to isolate hosts to MDGs then create one large MDG per disk controller
    - Assumes physical disks are all same size and speed and same RAID level
   MDG Performance Considerations:
    May make sense to create multiple MDGs if attempting to isolate workloads to different
    disk spindles
    With SATA disk drives avoid more then one MDG if possible
    We tend to see to many MDGs with too few MDisks and thus over driven MDisks
    We tend to see too few large physical disk spindles and I/O suffers
    - Avoid selling capacity and focus on spindle counts to meet workload requirements

     Page 21

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Disk Controller Best Practices

  When adding disk drives to an existing disk system consider adding
    the new MDisks to existing MDGs versus creating additional MDGs
    Use Perl script to restripe VDisk extents evenly across all MDisks in MDG
    Go to: www.ibm.com/alphaworks and search on „svctools‟

  Managed Disk Group Extent Size
    Maximum cluster capacity is related to extent size
    16MB extent = 64TB and doubles for each increment in extent size e.g. 32MB = 128TB
     Strongly recommend minimum 128/256MB
    SPC benchmarks used 256MB extent
    Does not really affect performance supposedly
     Pick extent size and use for all MDGs
    Can‟t migrate VDisks between MDGs with different extent sizes
    - V4.3.x helps here with introduction of VDisk Mirroring

     Page 22

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Disk Controller Best Practices

   All MDisks in an MDG should have similar performance
     Create minimum of one MDG per disk controller
    Add MDisks with same drive size, speed, RAID type
   Preferred path for VDisks in an I/O Group can be tailored
     Default algorithm will usually provide good results
     SVC alternates VDisks across nodes to attempt to balance workload
    Use TPC to monitor node workload balance
      Override defaults to assign new VDisks to least used nodes
  Use striped mode VDisk layout in most cases
     Consider using sequential VDisks with applications/DBs that do their own
    striping
     Balance need for copy services with need for a few large VDisks
     Remember limit of 64MB/s per VDisk for FC
     Remember limit of 25MB/s per VDisk for MM/GM sync/resync
     Default balances load across MDisks and randomizes starting MDisk per
    VDisk
     Page 23

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    Server 1    Server 2    SVC Cabling
    A     B    A     B    Best Practice
    and Zoning

    SAN Fabric A    SAN Fabric B

  HOST ZONING    SVC CLUSTER
Create a SVC/Host zone    ZONING
for each server that
receives storage from    Create one zone in the
the SVC cluster.    RED fabric with all the
    SVC node ports cabled
Example:    I/O G-0    I/O G-1    to Fabric A and create    one zone in the BLUE
Zone Server 1 port A (RED)    1    2    1    2    fabric with all the SVCwith all SVC node port 1's.    node ports cabled to
    Node 1    Node 3    Fabric B.
Zone Server 1 port B (BLUE)
with all SVC node port 2's.    3    4    3    4    Example:

Zone Server 2 port A (RED)    All odd (RED) SVC node
with all SVC node port 3's.    1    2    1    2    ports in one zone and all
    even (BLUE) SVC node ports
Zone Server 2 port B (BLUE)    Node 2    Node 4    in one zone.
with all SVC node port 4's.    3    4    3    4    Note: For a cluster to be    SVC    *** NOTE ***    created and to operate
SVC supports a maximum of    Cluster    correctly all node ports must
256 host objects per I/O    be zoned together.
group thus a maximum of
1024 per cluster. The above    STORAGE
host    zoning    results    in    each
server    being    seen by    every    I/    MDisk Group 1 / DS4000_1    ZONING
O group and the default host
object creation behavior    VDisk 1    Create a SVC/Storage
results in each host object    zone for each storage
counting as one towards    subsystem virtualized
this 256 maximum.    A2    VDisk 3    by the SVC cluster.
To create more then 256    Example:
host objects in the clusteryou must zone a host to a    A1    MDisk1     MDisk2    MDisk3    MDisk4     MDisk5    MDisk6     MDisk7    MDisk8     MDisk9    MDisk10    MDisk11    MDisk12    MDisk13    Zone DS4000_1 controller
subset of the I/O groups,    / / / / / / / / / / / / /   B1    ports A1 and B1 with all SVC
you must assign the host    node ports 1 and 3 in the
object at host creation time    RED fabric.
to   that same    subset    of    IO
    B2    Zone DS4000_1 controllergroups    and then    you    must    VDisk 2
    ports    A2 and    B2 with    all    SVCassign    that host‟s    VDisks    to    Array1     Array2    Array3    Array4     Array5    Array6     Array7    Array8     Array9    Array10    Array11    Array12    Array13    node ports    2 and    4 in    theone of those    I/O groups    in
that same subset.    VDisk 4    BLUE fabric.

     Page 25

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC 连接XIV最佳实践

Page 26

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

SVC and XIV Best Practices

   Full 15 Module XIV Recommendations – 79TB Useable
    Use 2 interface host ports from each of the 6 interface modules
      Use ports 1 and 3 from each interface module
    Zone these 12 ports with all SVC node ports
     Create forty-eight LUNs of equal size each a multiple of 17GB
     1632GB approximately if using entire full frame XIV with SVC
     Create one Managed Disk Group per XIV using 1GB or larger extent size
      Large extent size ensures extent striped across all SATA disks even if some day XIV
    supports more then one frame with 180 spindles (e.g.. 5 frames and 900 spindles)
      Extent size really not critical and smaller size can be chosen if desired
     Recommend minimum of 256MB extent size to ensure an extent is striped across all 180
    spindles in single frame, but again not required since XIV stripes over all spindles anyway
    Map LUNs to SVC as 48 MDisks and add all of them to the one XIV MDG
     SVC will drive I/O to 4 MDisks/LUNs per each of the 12 XIV fibre ports
      This provides good queue depth on SVC to drive XIV adequately
     Create striped VDisks using all 48 MDisks in MDG

     Page 27

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

SVC and XIV Best Practices

  Six Module XIV Recommendations – 27TB Useable
    Use 2 interface host ports from each of the 2 active interface modules
      Use ports 1 and 3 from interface modules 4 and 5 (Interface module 6 is inactive)
    Zone these 4 ports with all SVC node ports
     Create 16 LUNs of equal size each a multiple of 17GB
     1632GB approximately if using entire XIV with SVC
     Create one Managed Disk Group per XIV using 1GB or larger extent size
      Large extent size ensures extent striped across all SATA disks even if some day XIV
    supports more then one frame with 180 spindles (e.g.. 5 frames and 900 spindles)
      Extent size really not critical and smaller size can be chosen if desired
     Recommend minimum of 256MB extent size to ensure an extent is striped across all 180
    spindles in single frame, but again not required since XIV stripes over all spindles anyway
    Map LUNs to SVC as 16 MDisks and add all of them to the one XIV MDG
     SVC will drive I/O to 4 MDisks/LUNs per each of the 4 XIV fibre ports
      This provides good queue depth on SVC to drive XIV adequately
     Create striped VDisks using all 16 MDisks in MDG

     Page 28

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

SVC and XIV Best Practices

  Nine Module XIV Recommendations – 43TB Useable
    Use 2 interface host ports from each of the 4 active interface modules
      Use ports 1 and 3 from interface modules 4,5,7,8 (Interface modules 6 and 9 are inactive)
    Zone these 8 ports with all SVC node ports
     Create 26 LUNs of equal size each a multiple of 17GB
     1632GB approximately if using entire XIV with SVC
     Create one Managed Disk Group per XIV using 1GB or larger extent size
      Large extent size ensures extent striped across all SATA disks even if some day XIV
    supports more then one frame with 180 spindles (e.g.. 5 frames and 900 spindles)
      Extent size really not critical and smaller size can be chosen if desired
     Recommend minimum of 256MB extent size to ensure an extent is striped across all 180
    spindles in single frame, but again not required since XIV stripes over all spindles anyway
    Map LUNs to SVC as 26 MDisks and add all of them to the one XIV MDG
     SVC will drive I/O to 3 MDisks/LUNs on each of 6 ports and 4 on the other 2 XIV fibre ports
      This provides good queue depth on SVC to drive XIV adequately
     Create striped VDisks using all 26 MDisks in MDG

     Page 29

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

SVC and XIV Performance Results

  Random Reads and Writes
    No statistically significant performance difference with/without SVC
  Sequential Writes
    4K block size - SVC increases performance by 192%
    8K block size - SVC increases performance by 88%
    16K block size - SVC increases performance by 15%
    32K block size - SVC decreases performance by 17%
    64K block size - SVC decreases performance by 28%
  Sequential Reads
    4K block size - SVC increases performance by 61%
    8K block size - SVC increases performance by 24%
    16K block size - No significant difference with/without SVC
    32K block size - No significant difference with/without SVC
    64K block size - SVC decreases performance 5%

     Page 31

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC迁入步骤

Page 33

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

SVC迁入实施步骤参考

  迁入前准备工作
    前期SAN规划/存储阵列规划/SVC配置规划,相关人员到位
    兼容性检查,必要的设备微码升级(交换机/磁盘阵列)
    SVC上架上电,健康检查,初始化SVC集群
     SVC zone配置(Host zone/Storage zone/Internal zone/inter-cluster zone)
     在SVC上创建Host
    EMC CX上为SVC建立新的Storage Group,加入SVC节点的WWPN
     准备AIX主机版本所对应SDDPCM
  迁入实施
    停止应用,卸载VG,删除原有PV逻辑设备
     Disable主机和CX直连的Zone
     在CX上将原有的LUN从原主机Storage Group删除,加入到SVC的Storage Group当中
     在SVC发现新的LUN,使用Image模式导入
     将导入的Image模式Volume映射给建好的主机
     主机上卸载原有多路径软件,安装Sddpcm,使用Cfgmgr识别新的PV,Importvg
    启动应用,检查数据
  迁入后续工作
    条带化性能优化
    卷镜像本地保护机制建立
    快照备份机制建立
    容灾机制建立

     Page 34

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC EasyTier

    最佳实践

Page 35

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Easy Tier Best Practice

 Easy Tier between SSD and SAS or FC drives will be supported
      Nothing in the product will disallow other combinations
      Example: SAS to NL SAS allowed but will not be tested
       Using Easy Tier with other disk combinations could lead to unpredictable performance and
    should be tested before production implementation
      Easy Tier algorithms are “tuned specifically” to optimize with SSDs involved
 Not recommended to run Easy Tier in multiple disk controller levels
     Example: At SVC and Storwize V7000 with DS8000 backend on the same
    Volumes
 Easy Tier is designed to work with either SVC / Storwize V7000 internal
  SSDs or SAN based external SSDs
 Striped Volume can have Easy Tier set to on/off (default is on)
      Sequential and Image volumes will not be managed by Easy Tier
 Pool can have Easy Tier set to on/auto/off (default is auto)
        If set to “ON” rather than the default Auto, a single pool will be measured

 36  Page 36

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Easy Tier Best Practice

 Image and Sequential Volumes can be measured but NOT managed by Easy
   Tier
 Easy Tier is supported for FlashCopy source and target and Metro or Global
   Mirror primary and secondary Volumes
     MM or GM secondary Volumes do not inherit characteristics of primary as part of
     DR activities
      Example: If secondary becomes primary and usage changes the Easy Tier will have to
    adjust the extents over time to accommodate the new access patterns
 Easy Tier is supported on mirrored Volumes
     Both copies are managed by Easy Tier independently
 Easy Tier is supported for Thin Provisioned Volumes
     Only the real storage will be subject to management
 Volume migrate
     Management of the Volume will be disabled during a migration
     Measurement of the Volume will reflect the status of the source storage pool
    until the migration completes

     Page 37

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC 数据复制服务

    最佳实践

Page 38

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – FlashCopy Best Practices

  FlashCopy
     Background copy rate is configurable and default is 50 meaning 2MBs per
    VDisk
      Customers sometimes complain it is taking a long time to do a full copy
     Can dynamically change the copy rate up to a maximum of 64MBs per VDisk
      Balance speed of copy versus impact on production applications

     Page 40

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – Multiple-cycling Global Mirror

    1) Initial GM Cycle Started at
    Production host    6pm Oct. 10

    2) Initial synchronization
    completes at 6am Oct. 11
    Host I/O
    3) Freeze time will show 6pm
    Oct. 10 so RPO is 12 hours
    4) Change volumes reset
    5) Next cycle begins
    immediately since more then
    five minutes has passed    Global Mirror Relationship
    Ay B C D E F G    Ay B C D E F G    Cycle Period 5 Minutes    6) May be lots of changes to
 256K    H  I J K L M N    H  I J K L M N   send from last 12 hours butGrains    Inconsistent_copyingConsistent_copying statestate    RPO will get smaller as GM
     O P Q R S T Uz    O P Q R S T Uz   progresses through cycles
    Change
    Primary Volume    Secondary Volume    volume

    FlashCopy  A U    FlashCopy  A U
    „nocopy‟    „nocopy‟
    Mapping     Change    Mapping    Change
    Volume    Volume

    A10 0 0 0 0 0 0  AAAA1000 1000 1000 1000 1000 1000 1000
GM Bit  0 0 0 0 0 0 0  1000 1000 1000 1000 1000 1000 1000
 Maps
    0 0 0 0 0 0 U01  1100 1100 1100 1100 1100 1100 UUUU1110
    Page 41

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – Change Volumes

 Change volumes are used to record changes to the Primary and Secondary volumes of
  a remote copy relationship
 FlashCopy mapping exists between a Primary and its Change volume and a Secondary
  and its Change volume

    RC Relationship    Primary    Secondary

    volume    volume

    Change    Change

    volume    volume
    FlashCopy    FlashCopy
    mapping    mapping

 Change volume requirements
   Must be same virtual size and in the same I/O group as the Primary or Secondary volume of a
    remote copy relationship
    The Change volume will be Thin Provisioned (TP)
   Can not be used for host I/O and cannot be mapped to a host
   Can not be used by remote copy or FlashCopy
 FlashCopy mapping is for internal use
   User cannot manipulate it like a normal FlashCopy mapping
   Most CLI commands will fail
   Uses „nocopy‟ option so minimal real capacity used on TP change volumes
     Page 42

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – Multiple-cycling Global Mirror

  最大 RPO

     如果GM复制每次都能在“cycling period”时间内完成,那么最大RPO = 2 * cycling period

     否则, 最大RPO = 以前所有未完成复制的cycling period 的总和+当前的cycle times

   当前RPO: 用lsrcrelationship查看 freeze time,再计算

      Cycle period 是缺省5分钟,并且在 6:00am发起第一个Cycle,此时并没有时Freeze Time

     6:03am第一个Cycle的拷贝完成,那么此刻的Freeze time是6:00am,并且RPO是3分钟

     当第二个Cycle在6:05am开始,此刻RPO变为5分钟( Freeze time 仍然是6:00am )

     如果第二个Cycle的复制在6:12am还未完成,那么此刻RPO将变成12分钟(这时6:00am仍然是上次拷贝完成的完整数据)

     在 6:13am第二个Cycle的复制完成了,那么RPO将立刻减少到8分钟,因为6:05am发起的第二个Cycle已经复制完成,Freeze
    Time已经变为6:05am

     由于从6:05~6:13am已经超过第三个Cycle发起的时间,第三个复制将立刻开始

    6:00     6:03    6:05    6:12     6:13
    Freeze时间点

    复制完成时间点

    Cycling 0    Cycling 1    Cycling 3

     Page 43

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – Replication Best Practices

    Distance: MM <303KM, GM <8000KM
    Use Fibre Channel extenders,SAN routers,DWDM

    round-trip latency between sites cannot exceed 80 ms

    Default link tolerance in noncycling Global Mirror is 5
    minutes

    Metro Mirror and Global Mirror require a specific
    amount of bandwidth for intersystem heartbeat traffic

    Metro Mirror or noncycling Global Mirror:
    bandwidth between two sites must meet the peak
    workload requirements and maintain the maximum
    round-trip latency between the sites

 Table 1. Intersystem heartbeat traffic in Mbps    multiple-cycling Global Mirror:
   System 1    System 2    bandwidth between two sites according to RPO need
    2 nodes     4 nodes     6 nodes     8 nodes    RPO minutes to hours
 2 nodes     2.6    4.0    5.4    6.7    For example: consider the average write workload
 4 nodes     4.0    5.5    7.1    8.6    when application systems are busy and the required
 6 nodes     5.4    7.1    8.8    10.5    initial synchronization copy bandwidth
 8 nodes     6.7    8.6    10.5    12.4

    Redundancy link can tolerate single failures

     Page 44

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – Replication Best Practices

  Bandwidth Considerations
     If the SAN network bandwidth is too small to handle the traffic then
    application write I/O response time may be elongated
    For SVC noncycling GM must support short term „Peak Write‟ bandwidth
    requirements or expect write performance delays
     SVC noncycling GM much more sensitive to lack of bandwidth than DS8000
    - Bursts should exceed bandwidth for a „few‟ minutes only
    - Default link tolerance in GM is 5 minutes
      Pipe must be able to handle normal and peak write I/O
    - Even after loss of redundant link where no interruption to operation is required
    Need to consider initial sync and re-sync workload as well
     Requires SCORE/RPQ if data change rate will exceed communication
    bandwidth or round trip latency exceeds 80ms
  Bandwidth configurable in SVC based on pipe between clusters
    Only affects initial sync and any resyncs
    Set bandwidth setting to 30-50% of pipe capacity initially

     Page 45

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Copy Services – Replication Best Practices

  Metro/Global Mirror background copy rate is pre-defined
    Per VDisk limit is 25MB/s
    Maximum per I/O Group is roughly 250MB/s

  Be careful using slower disk subsystem for the secondary VDisks for
    high performance primary VDisks
    SVC cache may not be able to buffer all the writes
      Flushing cache writes to SATA may slow I/O at production site

  Use TPC to determine change rate for bandwidth sizing

     Page 46

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
SVC 三站点HA+DR(HACMP/XD自动切换)
    HACMP/XD实现DR全自动切换

    Host Node    Host Node    Host Node

    Oracle RAC

    SVC    SVC Cluster
    Cluster

    0101101010010101010101010010001001FC or    SAN    SAN    SAN
    extension

    SVC
    Cluster
    (split IO    010110101010    01011010101
    group)    0101101010010101

    SVC Metro Mirror
    SVC VDM    SVC Global Mirror
    Vendor_Y    Vendor_Z
   Vendor_X

    Site 1    Site 2    Site 3
    Management LAN

    SVC Console    IP
    Page 47
    FC

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
SVC容灾解决方案的优势

 IBM SVC解决方案优势:

  架构清晰,管理简单。
  节约投资,有效保护投资成本
    存储HA+DR (1:1:1)
    license投资不会随硬件的更换而丢失。(VDM免费,MM/GM永久有效)
  存储HA 任意存储损坏不会影响DR
  当DR初始化同步完成后,不需要再次Initial Copy。
   各种灾难场景
   两边存储设备的到期替换
  具有独特领先的存储服务级别(SLA)保障以应对各个数据保护阶段及灾
  难场景。

    Page 48

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC的Quorum disks

    最佳实践

Page 49

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
Concept of Quorum disks
 The cluster uses the quorum disk for two purposes:
    • Quorum disks are used when there is a problem in the SAN fabric or when nodes are shut
     down, leaving half of the nodes remaining in the cluster. A quorum disk determines which
    group of nodes stops operating and processing I/O requests.
    • Hold a copy of important cluster configuration data.
    Just over 256 MB is reserved for this purpose on each quorum disk candidate.
    Need for T3 recovery.
 The cluster automatically chooses three MDisks as quorum disk candidates.
    • There is only one active quorum disk that is used to determine which nodes operate as the
    cluster.
    • The purpose of the other quorum disk candidates is to provide redundancy.
 Running an SVC cluster without a quorum disk can seriously affect operation.
    • A lack of available quorum disks for storing metadata will prevent any migration operation:
    Migrating multiple extents (within a storage pool)
    Migrating extents off an MDisk that is being deleted(including a forced MDisk delete)
    Migrating a volume between storage pools
    Migrating the volume to image mode
    Migrating a volume between I/O Groups
    Monitoring the migration progress
    • Mirrored virtual disks (VDisks) also are taken offline when all the quorum disks are on a
    single controller that experiences a failure, because synchronization status for mirrored
     Pagevolumes50    is recorded on the quorum disk.

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Quorum disks best practice

 Must set quorum disks on multiple controllers to avoid the possibility of losing all of
   the quorum disks with a single failure.
 follow guidelines for changing the MDisk that are assigned as quorum disk
   candidates:
    •  It must be in managed mode (no image mode disks).
    • Ensure that the status of the MDisk that is being set as a quorum disk is online before
    setting it as the quorum disk.
    •  It must have sufficient free extents to hold the cluster state information, plus the stored
    configuration metadata.
    •  It must be visible to all of the nodes in the cluster.
    • When possible, distribute the quorum candidate disks so that each MDisk is provided by a
    different storage system. For a list of storage systems that support quorum disks, refer to
    the Supported Hardware List.
    • Wait at least two minutes between setting quorum disks. This delay allows time for the
    update to the quorum disk to complete before setting another quorum disk.
 An SVC cluster automatically assigns quorum disk candidates, but it is good
   practice to review the quorum disk assignments when adding new storage to a
   cluster or removing existing storage.

     Page 51

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Additional guidance for split-cluster configurations

 In the general case, where the nodes in a cluster have been split between sites,
   the SVC cluster should be configured such that:
    •  Site 1: Half of SVC cluster nodes + one quorum disk candidate
    •  Site 2: Half of SVC cluster nodes + one quorum disk candidate
    •  Site 3: Active quorum disk
    • This configuration ensures that there is always a quorum disk available, even after a
    single site failure.

     Page 52

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
  SVC – How Quorum Disks Affect Availability (1)

    Failure    Failure
    Domain 1    Domain 2    1) Loss of active quorum:
    SVC selects another quorum
    Continuation of operations

    2) Loss of storage system:
    Loss of active quorum
    ISL 1
    SVC selects another quorum
    Continuation of operations
    Mirrored Volumes continue

    TotalStorage    Storage Engine 336    TotalStorage    Storage Engine 336
    operation but may take
    Node 1    Node 2    60sec or more since active
    quorum disk failed

    Note: The loss of all quorum
    ISL 2    disks will not cause the
    cluster to stop as long as
    there are a majority of the
    nodes operational in the
    cluster. However, mirrored
    Volumes will likely go
    Volume    Mirroring    offline. This is why you
    would manually configure
    the cluster so the quorum
    disk candidates are located
    on disk systems in bothSVC Quorum 3    SVC Quorum 2 SVC Quorum 1
    failure domains.    Active Quorum

    Page 53

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
  SVC – How Quorum Disks Affect Availability (2)

    Failure    Failure
    Domain 1    Domain 2    Lose of Failure Domain 1 :
    Active quorum not affected
    Continuation of operations

    Lose of Failure Domain 2:
    ISL 1    Active quorum lost
    Half of nodes lost
    Loss of cluster majority

    TotalStorage    Storage Engine 336    TotalStorage    Storage Engine 336    Node 1 can not utilize
    quorum candidate to    Node 1    Node 2    recover and survive
    Node 1 shuts down and
    cluster stopped
    ISL 2
    May not be recoverable
    and may require cluster
    rebuild and data restore
    from backups
    No Active
    Quorum   Volume    Mirroring
    No Access to
    Data on Disk
SVC Quorum 3    SVC Quorum 2 SVC Quorum 1
Active Quorum    Active Quorum

    Page 54

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
  Current Supported Configuration for Split I/O Group

    Failure    Failure    Failure
    Domain 1    Domain 2    Domain 3

    Automated failover
    with SVC handling
    The loss of:
    - SVC node
    - Quorum disk    ISL 1
    - Storage subsystem

    TotalStorage    Storage Engine 336    TotalStorage    Storage Engine 336    Can incorporate
    MM/GM to provide
    Node 1    Node 2
    disaster recovery
    - 3 site like capability
    ISL 2

    Disk system
    that supports
    “Extended Quorum”
    Volume    Mirroring

    SVC Quorum 1
SVC Quorum 3    SVC Quorum 2 SVC Quorum 1    Active Quorum
Active Quorum    Active Quorum

    Page 55

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER
SVC Split I/O Group Summary

    Site 1    Site 2    Site 3    Cluster Status
    SVC Node 1    SVC Node 2    Quorum disk

    Operational    Operational    Operational    Operational, optimal

    Failed    Operational    Operational    Operational, Write cache disabled

    Operational    Failed    Operational    Operational, Write cache disabled

    Operational    Operational    Failed    Operational, Write Cache enabled, but
    different active Quorum disk

    Operational, link to Site 2    Operational, link to Site 1 failed:     Operational    Whichever node accesses the active
    failed: Split Brain    Split Brain    quorum disk first survives and the partner
    node goes offline

    Operational    Failed same time with Site 3    Failed same time with Site 2   Stopped

    Failed same time with Site 3    Operational    Failed same time with Site 1   Stopped     Page 56

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC Stretch Cluster

    最佳实践

Page 57

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Extension of Currently Supported Configuration

    User chooses number of ISLs on SAN

    Server Cluster 1    Server Cluster 2

    SAN    SAN
    Active DWDM
    over shared
    single mode
    fibre(s)

    SVC + UPS    0-10 KM Fibre Channel distance    SVC + UPS
    supported up to 8Gbps

    11-20KM Fibre Channel distance
    SAN    supported up to 4Gbps    SAN

    21-40KM Fibre Channel distance
    supported up to 2Gbps

    User chooses number of ISLs on SAN

    Two ports per SVC node attached to local SANs
    Two ports per SVC node attached to remote SANs via DWDM
    Hosts and storage attached to SANs via ISLs sufficient for workload
     Page 58    3rd site quorum (not shown) attached to SANs

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Stretch Cluster – Distance

The new stretch cluster configuration will support distances of up to 300KM
  Same recommendation as for Metro Mirror

However typical deployment of stretch cluster will only be 1/2 or 1/3 of this distance
  because of added latency and buffer credit limitations/considerations

     Page 59

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Configuration With 4 Switches at Each Site

    User chooses number of ISLs on public SAN

    Server Cluster 1    Server Cluster 2

    Public    Private  1 ISL per I/O group     Private     Public
    Configured as trunk    SAN     SAN    SAN     SAN

    SVC + UPS    SVC + UPS

    Public    Private  1 ISL per I/O group     Private     Public
    SAN    SAN     Configured as trunk   SAN    SAN

    User chooses number of ISLs on public SAN

    Two ports per SVC node attached to public SANs
    Two ports per SVC node attached to private SANs
    Hosts and storage attached to public SANs
     Page 60    3rd site quorum (not shown) attached to public SANs

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Configuration Using CISCO VSANs

    Switches are partitioned using VSANs
    Server Cluster 1    Server Cluster 2

    Public   Private    Private  Public
    VSAN  VSAN    VSAN  VSAN

    SVC + UPS    SVC + UPS

    Public   Private    Private  Public
    VSAN  VSAN    VSAN  VSAN

    Note ISLs/Trunks for private VSANs are dedicated
    rather than being shared to guarantee dedicated
    bandwidth is available for node to node traffic
     Page 61    3rd site quorum (not shown) attached to public VSANs

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

Configuration Using Brocade Virtual Fabrics

    Physical switches are partitioned into
    two logical switches
    Server Cluster 1    Server Cluster 2

    Public   Private    Private  Public
    SAN   SAN    SAN   SAN

    SVC + UPS    SVC + UPS

    Public   Private    Private  Public
    SAN   SAN    SAN   SAN

    Note ISLs/Trunks for private SANs are dedicated
    rather than being shared to guarantee dedicated
    bandwidth is available for node to node traffic
     Page 62    3rd site quorum (not shown) attached to public SANs

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

    SVC与VMware 最佳实践

Page 63

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

VMware Best Practise

  SVC supports vSphere V4/5 MRU, Fixed (default now) and Round-Robin
  SRM supported with Metro/Global Mirror
  SVC support VAAI(vStorage API for Array Integration)

 HW accelerated ZERO    HW accelerated Copy    HW accelerated Locking

    2-10x lower    2-10x better
    number of IO    Copy Area A to Area B    Fill Area with 0    data movement
    operations    10-100x
    better
    01011010101  A    metadata
    00000000000    B    scaling

    (SCSI Write Same)    (SCSI XCopy)    (Atomic Operation instead of Reserve/Release)

    客户行业    测试环境    使用VAAI之前   使用VAAI之后   时间减少(%)

     金融行业    2 VMs    433 Sec    180 Sec    59%

     电力行业    2 VMs    944 sec    517 sec    45%

     石油行业    40 VMs    1 hour    20 min    67%     Page 65

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

VAAI--full copy

 Without hardware-accelerated     With hardware-accelerated
    full copy (clone)    full copy (clone)

     Page 66

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

VAAI--Block zeroing

 Block zeroing

     Page 67

    实施专家级课程    Storage Cloud – IBM SAN VOLUME CONTROLLER

VAAI--Hardware-acceleratedLocking

 Without Hardware-assisted    With Hardware-assisted
   Locking    Locking

     Page 68

Thank
 You!

    © Copyright IBM Corporation 2009