正文文本
Server
    Lenovo OEM/Extended SEL Events
    Design Specification

    Revision:   0.1
    Initial Writer: Lawrence Li
    Initial Date: 1/3, 2017

Document Control Information
    Role    Name    Date     Company /     E-mail Address
    Dept
    Author
    PD Development
    SW
    PA
    Approver

    Lenovo OEM/Extended SEL Events Design Specification
Copy Rights

    Copyright © 2001 – 2014 Lenovo Group
     All Rights Reserved.
   Lenovo Group
   No.6 Chuang Ye Road, Haidian District,Beijing China  100085

    This publication contains proprietary information which is protected by copyright. No part of this publication may be reproduced,
    transcribed, stored in a retrieval system, translated into any language or computer language, or transmitted in any form whatsoever
    without the prior written consent of the publisher, Lenovo Group and American Megatrends, Inc.

   Trademark and Copyright Acknowledgments
     All product names used in this publication are for identification purposes only and are trademarks of their respective Companies.

    2

    Lenovo OEM/Extended SEL Events Design Specification
Revision History

 Revision     Date    Author    Description of Changes
 0.1    2017/1/3    Lawrence    Initial Release for Purley

    3

    Lenovo OEM/Extended SEL Events Design Specification
Table of Contents

COPY RIGHTS ...................................................................................................................................................................... 2

REVISION HISTORY .............................................................................................................................................................. 3

TABLE OF CONTENTS ........................................................................................................................................................... 4

1.   POST ERROR LOG WITH LENOVO EXTENDED SEL EVENT FORMATS ................................................................................ 5

   1.1    QPI RC ERRORS ..................................................................................................................................................................... 5
   1.2   MRC ERRORS ........................................................................................................................................................................ 6
   1.3     PCIE PERFORMANCE DEGRADATION .......................................................................................................................................... 7

2.   POST ERROR LOG WITH STANDARD SEL EVENT FORMATS ............................................................................................. 8

   2.1    MICROCODE ERRORS .............................................................................................................................................................. 8
   2.2   BMC REQUESTED NMI ........................................................................................................................................................... 8
   2.3    CPU EXCEPTION .................................................................................................................................................................... 8
   2.4   NO BOOTABLE DEVICE FOUND .................................................................................................................................................. 8
   2.5   CMOS CLEARED OR RTC RESET .............................................................................................................................................. 9
   2.6   ME VERVISON MISMATCH DETECTED ......................................................................................................................................... 9

3.  RUNTIME ERROR LOGGING AND FRU ISOLATING ........................................................................................................ 10

   3.1    MEMORY ERROR .................................................................................................................................................................. 10
   3.2    AER (PCIE DEVICES) ............................................................................................................................................................ 11
   3.3    RUNTIME PROCESSOR ERRORS ............................................................................................................................................ 13
   3.4     IIO CORE ............................................................................................................................................................................ 14
   3.5     IIO-COHERENCE INTERFACE (IIO QPI)...................................................................................................................................... 15
   3.6     IIO-VTD ............................................................................................................................................................................. 16

4.   SYSTEM FAULT LED .................................................................................................................................................... 17

    4

    Lenovo OEM/Extended SEL Events Design Specification

     1.   POST ERROR LOG WITH LENOVO EXTENDED SEL EVENT FORMATS

    This  section  describes  the SEL formats  of  different Lenovo Extended SEL  events. SEL viewer  utility
development teams can use this document.
    1.1  QPI RC ERRORS

SEL:
Sensor Type    0x7 Processor

Sensor Number    Per BMC spec design

Event Dir/Type     0x6F

Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM value)
    Bit[3:0] = Error Type (PROCESSOR CONFIGURATION ERROR)

Event data 2    Bit[7:2] = Reserved
    Bit[1:0] =
    0 – QPI Warning
    1 – QPI Non-Fatal Error
    2 – QPI Fatal Error

Event data 3    Bit[7:4] = CPU Socket Number
    Bit[3:0] = QPI Port number

ExtSEL:

Sensor Type    0x7 Processor

Sensor Number    Per BMC spec design

Event Dir/Type    0x70 – OEM Event

Event Data 1-3    Filled by BMC

Extended SEL    0x5 - Error Type (PROCESSOR CONFIGURATION ERROR)
Data 1
Extended SEL    Bit[7:2] = Reserved
Data 2    Bit[1:0] =
    0 – QPI Warning
    1 – QPI Non-Fatal Error
    2 – QPI Fatal Error

Extended SEL    Bit[7:4] = CPU Socket Number
Data 3    Bit[3:0] = QPI Port number

Extended SEL    Bit[7:0] = Major Code based on Purley RC User Guide.

    5

    Lenovo OEM/Extended SEL Events Design Specification
Data 4
Extended SEL    Bit[7:0] = Minor Code based on Purley RC User Guide.
Data 5

    1.2  MRC ERRORS

SEL:
Sensor Type    0xC Memory

Sensor Number    Per BMC spec design

Event Dir/Type     0x6F

Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM value)
    Bit[3:0] = 0x7 - Error Type (MEMORY CONFIGURATION ERROR)

Event data 2    Bit[7:4] = CPU Socket Number
    Bit[3:0] = Memory Channel number

Event data 3    Bit[7:4] = DIMM slot number
    Bit[3:0] = DIMM Rank number

ExtSEL:

Sensor Type    0xC Memory

Sensor Number    Per BMC spec design

Event Dir/Type    0x70 – OEM Event

Event Data 1-3    Filled by BMC

Extended SEL    0x7 - Error Type (MEMORY CONFIGURATION ERROR)
Data 1
Extended SEL    Bit[7:2] = Reserved
Data 2    Bit[1:0] =
    0 – MRC Warning
    1 – MRC Non-Fatal Error
    2 – MRC Fatal Error

Extended SEL    Bit[7:4] = CPU Socket Number
Data 3    Bit[3:0] = Memory Channel number

Extended SEL    Bit[7:4] = DIMM slot number
Data 4    Bit[3:0] = DIMM Rank number

    6

    Lenovo OEM/Extended SEL Events Design Specification
Extended SEL    Bit[7:0] = Major Code based on Purley RC User Guide.
Data 5
Extended SEL    Bit[7:0] = Minor Code based on Purley RC User Guide.
Data 6

    1.3  PCIE PERFORMANCE DEGRADATION

Extended SEL format:
Sensor Type    0x21 Slot / Connector

Sensor Number    Per BMC spec design

Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM value)
    Bit [3:0] =  0 (Error Type - PCIE Performance Degradation)

Event data 2    Bit[7-3] = Reserved
    Bit[2:0] =  Degradation Type
    BIT 0 –  Link speed degraded
    BIT 1 –  Link width degraded
    BIT 2 – Link training failed

Event data 3    Bit[7:0]  =   Slot Number

    7

    Lenovo OEM/Extended SEL Events Design Specification
     2.   POST ERROR LOG WITH STANDARD SEL EVENT FORMATS

    These messages are covered under the IPMI spec, but may have additional OEM data included.
    2.1  MICROCODE ERRORS

Sensor Type    0x7 Processor Microcode

Sensor Number    Per BMC spec design

Event data 1    Bit[7:4] = 0xF
    Bit[3:0] = 0x5

Event data 2    Bit[7:6] = Reserved
    Bit[5:0] = CPU number

Event data 3    0x2

    2.2  BMC REQUESTED NMI

Sensor Type    0x13 Critical Interrupt

Sensor Number    Per BMC spec design

Event Type    0x6f  Sensor Specific Offset

Event data 1    Bit[7:4] = 0x0 (Indicates that OEMEvData2 and OEMEvData3 are unspecified)
    Bit[3:0] = 0x03 Software SMI

Event data 2    Bit [7:0] = 0

Event data 3    Bit [7:0]  = 0

    2.3  CPU EXCEPTION

Sensor Type    0x0F System Firmware Progress

Sensor Number    Per BMC spec design

Event Type    0x6F

Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 is OEM values)
    Bit [3:0] = 0x1 System Firmware Hang

Event data 2    Bit[7:0] = 0 unspecified

Event data 3    Bit[7:0] = Exception Number

    2.4  NO BOOTABLE DEVICE FOUND

Sensor Type    0x1E Boot Error

    8

    Lenovo OEM/Extended SEL Events Design Specification
Sensor Number    Per BMC spec design

Event Type    0x6f  sensor specific offset

Event data 1    Bit[7:4] = 0x0 (Indicates that OEMEvData2 and OEMEvData3 are unspecified)
    Bit[3:0] = 0x00  No Bootable media

Event data 2    Bit [7:0]  =  0xFF (unspecified)

Event data 3    Bit [7:0]  = 0xFF (unspecified)

    2.5  CMOS CLEARED OR RTC RESET

Record ID    Record ID
Record Type    02 – System Event Record
Timestamp    Timestamp
Generator ID    0x01
EvmRev    4
Sensor Type    0x29  Battery
Sensor Number    Per BMC spec design
Event    Dir    |  0x6F
EventType
Event data 1    Bit[7:4] - 0x0 - Indicates byte 2 and byte3 are reserved.
    Bit[3:0] – 0x1 - Battery failed.

Event data 2    Reserved

Event data 3    Reserved

Note: For runtime errors current BIOS supports logging both SEL and extended SEL events, as Lenovo current web
utilities does not support reading the extended SEL events.
    2.6  ME VERVISON MISMATCH DETECTED

Record ID    Record ID
Record Type    02 – System Event Record
Timestamp    Timestamp
Generator ID    0x01
EvmRev    4
Sensor Type    0x2B  Version Change
Sensor Number    Per BMC spec design
Event    Dir    |  0x6F
EventType
Event data 1    Bit[7:4] - 0x0 - Indicates byte 2 and byte3 are reserved.
    Bit[3:0] – 0x3 - Firmware or software incompatibility detected with associated Entity.

Event data 2    Reserved

    9

    Lenovo OEM/Extended SEL Events Design Specification
Event data 3    Reserved

     3.   RUNTIME ERROR LOGGING AND FRU ISOLATING

    3.1  MEMORY ERROR

Lenovo Correctable error Logging Policy:
     1. If system encounters 160 correctable errors in a DIMM rank in 10 seconds or 2560 errors in 24 hours, BIOS
will log one SEL log to BMC.
     2. If system encounters 1000 correctable errors in a DIMM rank in 10 seconds, then disable the SMI of the
memory controller. The memory connected to this controller will not report error until next reset.
     3. Memory Corrected/Uncorrected error are in same formats.

SEL:
Byte   Field    Description
1-2    Record ID    Record ID
3     Record Type    02 – System Event Record
4-7   Timestamp    Timestamp
8-9    Generator ID    0x21
10    EvmRev    4
11    Sensor Type    0xC Memory

12    Sensor Number    Per BMC spec design

13    Event Dir | EventType    0x6F
14    Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are
    OEM values)
    Bit[3:0] = Error Type
    Error Type:
    Correctable Memory Error: 0x00
    Uncorrectable Memory Error: 0x01
    Parity Error: 0x02
    Correctable Memory Error Logging Limit Reached: 0x05
15    Event data 2    Bit[0] = Current/Last Boot Error
    Current Boot : 0
    Last Boot    : 1
    Bit[2:1] = Memory Controller Number
16    Event data 3    Bit[7:6]: CPU Socket Number.
    Bit[5:4]: Channel Number.
    Bit[3:0]: DIMM Number.
*Note: This SEL will turn on fault LED.

ExtSEL
Byte   Field    Description
1-2    Record ID    Record ID
3    Record Type    0xDF – OEM System Event Record
4-7    Timestamp    Timestamp
8-9    Generator ID    0x21
10    EvmRev    0

    10

    Lenovo OEM/Extended SEL Events Design Specification
11     Sensor Type    0xC Memory

12     Sensor Number    Per BMC spec design

13     Event Dir | EventType    0x70
14     Reserved    1Byte (modified as 0xAA by BMC)
15     Reserved    1Byte (modified by BMC)
16     Resreved    1Byte (modified by BMC)
17     Ext Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3
    are OEM values)
    Bit[3:0] = Error Type
    Error Type:
    Correctable Memory Error: 0x00
    Uncorrectable Memory Error: 0x01
    Parity Error: 0x02
    Correctable Memory  Error Logging  Limit Reached:
    0x05
18     Ext Event data 2    Bit[0] = Current/Last Boot Error
    Current Boot : 0
    Last Boot    : 1
    Bit[2:1] = Memory Controller Number
19     Ext Event data 3    Bit[7:6]: CPU Socket Number.
    Bit[5:4]: Channel Number.
    Bit[3:0]: DIMM Number.
20-27  Ext Event data 4-11    MC Bank Status Register

28-35  Ext Event data 12-19    MC Bank Address Register

36-43  Ext Event data 20-27    MC Bank Misc Register

44     Ext Event data 28    MC Bank number

    3.2  AER (PCIE DEVICES)

SEL:
Byte    Field    Description
1-2     Record ID    Record ID
3    Record Type    02 – System Event Record
4-7     Timestamp    Timestamp
8-9     Generator ID    0x21
10     EvmRev    4
11    Sensor Type    SEL_SENS_TYPE_CRIT_ERR <0x13>

12    Sensor Number

    Per BMC spec design

13    Event Dir | EventType  0x6F

14    Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM

    11

    Lenovo OEM/Extended SEL Events Design Specification
    values)
    Bit[3:0] = Error Type
    Error Type
    PCI PERR    -    0x04
    PCI SERR    -    0x05
    Bus Correctable Error    -    0x07
    Bus Uncorrectable Error    -    0x08
    Bus Fatal Error    -    0x0A
15    Event data 2    Bit[7:0] = PCI bus number for failed device.

16    Event data 3    Bit[7:3] = PCI device number for failed device.
    Bit[2:0] = PCI function number for failed device.

ExtSEL

Byte    Field    Description
1-2     Record ID    Record ID
3    Record Type    0xDF – OEM System Event Record
4-7     Timestamp    Timestamp
8-9     Generator ID    0x21
10     EvmRev    0
11    Sensor Type    SEL_SENS_TYPE_CRIT_ERR <0x13>

12    Sensor Number    Per BMC spec design

13    Event Dir | EventType    0x70

14    Reserved    1Byte (modified as 0xAA by BMC)
15    Reserved    1Byte (modified by BMC)
16    Resreved    1Byte (modified by BMC)
17    Ext Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3
    are OEM values)
    Bit[3:0] = Error Type
    Error Type
    PCI PERR    -    0x04
    PCI SERR    -    0x05
    Bus Correctable Error    -    0x07
    Bus Uncorrectable Error    -    0x08
    Bus Fatal Error    -    0x0A
18    Ext Event data 2    Bit[7:0] = PCI bus number for failed device.

19    Ext Event data 3    Bit[7:3] = PCI device number for failed device.
    Bit[2:0] = PCI function number for failed device.
20-21   Ext Event data 4-5    Slot Infomation(Number)

22    Ext Event data 6    IsBridge

23-24   Ext Event data 7-8    SecondaryStatus

25-26   Ext Event Data Byte[9-10]    DeviceStatus

27-30   Ext Event Data Byte[11-14]    UncorrErrStatus Register

    12

    Lenovo OEM/Extended SEL Events Design Specification
31-34   Ext Event Data Byte[15-18]    CorrErrStatus Register

35-38   Ext Event Data Byte[19-22]    RootErrStatus Register

    3.3  RUNTIME PROCESSOR ERRORS

For MCA Banks IFU, DCU, DTLB and MLC Errors
SEL:

Byte   Field    Description
1-2    Record ID    Record ID
3     Record Type    02 – System Event Record
4-7   Timestamp    Timestamp
8-9    Generator ID    0x21
10    EvmRev    4
11     Sensor Type    0x7  PROCESSOR_SENSOR_TYPE
12     Sensor Number    Per BMC senor number Spec Design
13    Event Dir | EventType    0x6F
14    Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3
    are OEM values)
    Bit[3:0] = Error Type (5-PROCESSOR
    CONFIGURATION_ERROR)
15    Event data 2    Bit[7:4] = Socket Number
    Bit[3:0] = Bank Type (Please see below)
    Bank Type:
    0 (0000) - None
    1 (0001) - IFU
    2 (0010) - DCU
    3 (0011) - DTLB
    4 (0100) - MLC
    5 (0101) - PCU
    6 (0110) - IIO
    7 (0111) - CHA
    8 (1000) - KTI
16    Event data 3    Bit[7:4] = Processor Error Type
    (UNKNOWN/Cache/TLB/BUS/Micro Arch)
    Bit[3:0] = Error Severity (Correctable/Uncorrectable)
    Error Severity:
    00 - Correctable Error
    01 - Fatal Error
    02 - Corrected Error

Extended SEL
Byte   Field    Description
1-2    Record ID    Record ID
3    Record Type    0xDF – OEM System Event Record
4-7    Timestamp    Timestamp
8-9    Generator ID    0x21
10    EvmRev    0
11     Sensor Type    0x7  PROCESSOR_SENSOR_TYPE
12     Sensor Number    Per BMC senor number Spec Design

    13

    Lenovo OEM/Extended SEL Events Design Specification
13     Event Dir | EventType    0x70
14     Reserved    1Byte (modified as 0xAA by BMC)
15     Reserved    1Byte (modified by BMC)
16     Resreved    1Byte (modified by BMC)
17     Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3
    are OEM values)
    Bit[3:0]     =    Error     Type     (5-PROCESSOR
    CONFIGURATION_ERROR)
18     Event data 2    Bit[7:4] = Socket Number
    Bit[3:0] = Bank Type (Please see below)
    Bank Type:
    0 (0000) - None
    1 (0001) - IFU
    2 (0010) - DCU
    3 (0011) - DTLB
    4 (0100) - MLC
    5 (0101) - PCU
    6 (0110) - IIO
    7 (0111) - CHA
    8 (1000) - KTI
19     Event data 3    Bit[7:4] = Processor Error Type
    (UNKNOWN/Cache/TLB/BUS/Micro Arch)
    Bit[3:0] = Error Severity (Correctable/Uncorrectable)
    Error Severity:
    00 - Correctable Error
    01 - Fatal Error
    02 - Corrected Error
20-27  Ext Event data 4-11    MC Bank Status Register

28-35  Ext Event data 12-19    MC Bank Address Register

36-43  Ext Event data 20-27    MC Bank Misc Register

44     Ext Event data 28-29    MC BANK number

    3.4   IIO CORE

SEL:
  Byte  Field    Description
  1-2   Record ID    Record ID
  3     Record Type    0x2 –System Event Record
  4-7   Timestamp    Timestamp
  8-9   Generator ID    0x21
  10   EvmRev    4
  11    Sensor Type    0x07 PROCESSOR_SENSOR_TYPE

    14

    Lenovo OEM/Extended SEL Events Design Specification
  12    Sensor Number

    Per BMC spec design

  13    Event Dir | EventType    0x6F

  14    Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM
    values)
    Bit[3:0] = Error Type (5-PROCESSOR CONFIGURATION_ERROR)

  15    Event data 2    Bit[7:4] = CPU Socket Number.

    Bit[3:0] = Reserved

  16    Event data 3    Error Sub Type
    c4h - Master abort address error
    c5h - Completor abort address error
    c6h - FIFO Overflow/Underflow error

    3.5  IIO-COHERENCE INTERFACE (IIO QPI)

SEL:
  Byte  Field    Description
  1-2   Record ID    Record ID
  3     Record Type     0x2 –System Event Record
  4-7   Timestamp    Timestamp
  8-9   Generator ID     0x21
  10   EvmRev    4
  11    Sensor Type     0x07 PROCESSOR_SENSOR_TYPE

  12    Sensor Number   Per BMC spec design

  13    Event   Dir    |  0x6F
    EventType
  14    Event data 1    Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM values)
    Bit[3:0] = Error Type (5-PROCESSOR CONFIGURATION_ERROR)

  15    Event data 2    Bit[3:0] = QPI Port number.
    Bit[7:4] = CPU Socket Number.
  16    Event data 3    Coherent Interface (IRP) Local Group Error code as per IvyBridge-EX 4S Processor
    External Design Specification (EDS) specification.
    B4h - Write Cache Detected ECC Correctable Error.
    C1h - Coherency Interface Protocol Layer Received Poisoned packet
    C2h - I/O module Write Cache uncorrectable Data ECC error
    C3h - I/O module CSR access crossing 32-bit boundary.
    D7h - Coherent Interface Protocol Layer Received Unexpected or Illegal Response/Completion
    DAh - Coherent Interface Protocol Layer Queue/Table Overflow or Underflow
    DBh - Coherent Interface Protocol Parity Error.

    15

    Lenovo OEM/Extended SEL Events Design Specification
    3.6  IIO-VTD

SEL
  Byte    Field    Description
  1-2    Record ID    Record ID
  3    Record Type    0x2 –System Event Record
  4-7    Timestamp     Timestamp
  8-9     Generator ID    0x21
  10    EvmRev    4
  11     Sensor Type    0x07 PROCESSOR_SENSOR_TYPE

  12     Sensor    Per BMC spec design
    Number

  13     Event   Dir    |  0x6F
    EventType
  14     Event data 1     Bit[7:4] = 0xA (Indicates that OEMEvData2 and OEMEvData3 are OEM values)
    Bit[3:0] = Error Type (5-PROCESSOR CONFIGURATION_ERROR)

  15     Event data 2   CPU Socket Number.

  16     Event data 3     Intel VT-d Local Group error code as per IvyBridge-EX 4S Processor
    External Design Specification (EDS)

    90h - Data Parity Error during Context Cache Lookup
    91h - Data Parity Error during L1 Lookup
    92h - Data Parity Error during L2 Lookup
    93h - Data Parity Error during L3 Lookup
    94h - TLB0 Data Parity Error
    95h - TLB1 Data Parity Error
    96h - Unsuccessful completion status received in the coherent interface
    97h - Illegal request to 0xFEE
    98h - Protected Memory region space violated status
    A0h - Intel VT-d spec defined errors

    16

    Lenovo OEM/Extended SEL Events Design Specification

4.   SYSTEM FAULT LED

    When BIOS detected listed system errors, BIOS or BMC will turn on system fault LED.
    •  QPI RC errors.
    •  MRC errors.
    •  Microcode Errors
    •  CPU Exception
    •  Runtime Processor Errors
    •   Uncorrected Memory Error
    •   IIO Core/ IIO-Coherence interface(IIO QPI)/IIO-Vtd Error

    17