AIX 在 ODM 设为 no_reserve 时仍下发单路径预留

症状

未对主机进行任何已知更改。
路径故障
进入 ASB:IOPF 的路径
SC_DISK_ERR9 和 SC_DISK_ERR10,附带感测数据 0118
预留冲突
devrsrv -c query -l hdiskXX 返回 ODM no_reserve,但实际预留为 single_path
LABEL: SC_DISK_ERR9
IDENTIFIER: B0EE9AF5
Resource Name: hdisk1024
Description
REQUESTED OPERATION CANNOT BE PERFORMED
SENSE DATA
0A00 2500 0000 0000 0000 0004 0000 0000 0000 0000 0000 0000 0118 0000 0000 0000
lsattr -El hdisk527 :-
pvid 00c3a085229ab91a0000000000000000 Physical volume identifier False
reserve_policy no_reserve Reserve Policy True
lsattr -El hdisk536 :-
pvid 00c3a085229ab91a0000000000000000 Physical volume identifier False
reserve_policy no_reserve Reserve Policy True
lsattr -El hdisk563 :-
pvid 00c3a085229ab91a0000000000000000 Physical volume identifier False
reserve_policy no_reserve Reserve Policy True
lsattr -El hdisk572 :-
pvid 00c3a085229ab91a0000000000000000 Physical volume identifier False
reserve_policy no_reserve Reserve Policy True
lsattr -El hdisk1023 :-
pvid 00c3a085229ab91a0000000000000000 Physical volume identifier False
reserve_policy no_reserve Reserve Policy True
lsattr -El hdisk1024 :-
pvid 00c3a085229ab91a0000000000000000 Physical volume identifier False
reserve_policy no_reserve Reserve Policy True
lsattr -El hdiskpower3 :-
pvid none Physical volume identifier False
reserve_policy no_reserve Reserve Policy used to reserve device on open. True
devrsrv -c query -l hdisk2

Device Reservation State Information ================================================== Device Name : hdisk2 Device Open On Current Host? : YES ODM Reservation Policy : NO RESERVE Device Reservation State : SINGLE PATH RESERVE Path Id of Reserved Path : 0

原因

Generic IBM ODM 最初设置了 single_path 预留,当安装 Dell EMC ODM 并将路径移至其下时,该预留未被释放。

解决方案

"devrsrv -c release -l hdiskXX" 将清除预留,且该预留不会再出现。

其他参考:https://www.ibm.com/docs/en/aix/7.2?topic=d-devrsrv-command

11 次浏览 更新于 2026-11-07

同组文章性能与故障案例

查看本组全部 6 篇

没有找到想要的答案?

上传日志让 AI 帮你诊断,或者在控制台里直接向 AI 提问。