正文文本
FUJITSU Storage
ETERNUS Multipath Driver (Windows Version)
    Installation Information

    Jan. 2022

    ETERNUS Multipath Driver Installation Information

    Contents

About ETERNUS Multipath Driver for Windows .......................................................................... 4
Supported Operation System (OS) Versions ............................................................................... 4
Supported Storage Systems ......................................................................................................... 5

 ETERNUS DX60 S2, ETERNUS DX80 S2, ETERNUS DX90 S2 ................................................................................ 5
 ETERNUS DX60 S3, ETERNUS DX100 S3, ETERNUS DX200 S3, ETERNUS DX200F, ETERNUS DX500 S3,
 ETERNUS DX600 S3 .................................................................................................................................................... 5
 ETERNUS DX60 S4, ETERNUS DX100 S4, ETERNUS DX200 S4, ETERNUS DX500 S4, ETERNUS DX600 S4 .. 6
 ETERNUS DX60 S5, ETERNUS DX100 S5, ETERNUS DX200 S5, ETERNUS DX500 S5, ETERNUS DX600 S5 .. 6
 ETERNUS AF150 S3, ETERNUS AF250 S3/AF250 S2/AF250 .................................................................................. 6
 ETERNUS AF650 S3/AF650 S2/AF650 ....................................................................................................................... 6
 ETERNUS DX900 S5 .................................................................................................................................................... 6
 ETERNUS DX400 S2 series ........................................................................................................................................ 7
 ETERNUS DX8000 S2 series ...................................................................................................................................... 7
 ETERNUS DX8900 S4, ETERNUS DX8000 S3 series ............................................................................................... 7
Related Products Requirements .................................................................................................. 8

  Related Hardware Product Requirements ................................................................................................................ 8
  Related Software Product Requirements ............................................................................................................... 10
  Virtualization Environments ..................................................................................................................................... 10
Hyper-V environment .................................................................................................................. 11
Channel Adapter ID and Connection Points .............................................................................. 13

 ETERNUS DX60 S2 rear view ................................................................................................................................... 13
 ETERNUS DX60 S5, ETERNUS DX60 S4, ETERNUS DX60 S3 rear view ............................................................. 13
 ETERNUS DX100 S5, ETERNUS DX100 S4, ETERNUS DX100 S3 rear view ....................................................... 14
 ETERNUS DX200 S4, ETERNUS DX200 S3, ETERNUS DX200F, ETERNUS AF150 S3/AF250 S2/AF250,
 ETERNUS DX80 S2, ETERNUS DX90 S2 rear view ................................................................................................ 14
 ETERNUS DX200 S5, ETERNUS AF250 S3 ............................................................................................................. 15
 ETERNUS DX500 S5/DX500 S4/DX500 S3, ETERNUS DX600 S5/DX600 S4/DX600 S3, ETERNUS AF650
  S3/AF650 S2/AF650, ETERNUS DX8100 S3,ETERNUS DX400 S2 series rear view ............................................ 15
 ETERNUS DX 900 S5 rear view ................................................................................................................................ 16
 ETERNUS DX8100 S2 rear view ............................................................................................................................... 17
 ETERNUS DX8700 S2 front view .............................................................................................................................. 17
 ETERNUS DX8900 S4, ETERNUS DX8700 S3, ETERNUS DX8900 S3 rear view ................................................. 18
Assigned-/ Non-assigned-CM Type Storage Systems .............................................................. 21
Notes ............................................................................................................................................. 22
Multipath Driver Updates ............................................................................................................ 23

■Trademarks

Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries.
Linux is a trademark or registered trademark of Linus Torvalds in the United States and other countries.
Red Hat is a trademark or registered trademark of Red Hat, Inc. in the United States and other countries.
SUSE is a registered trademark of Novell, Inc. in the United States and other countries.
VMware is a registered trademark of VMware, Inc. in the United States and other countries.
UNIX is a registered trademark of X/Open Company, Ltd. in the United States and in other countries.
EXPRESSCLUSTER is a registered trademark of NEC Corporation in the United States and other countries.
SteelEye, SteelEye Technology, and LifeKeeper are registered trademarks of SteelEye Technology, Inc.
All other company/product names mentioned herein may be trademarks or registered trademarks of their respective holders and are used for
identification purposes only.

Copyright 2022 FUJITSU LIMITED

    ETERNUS Multipath Driver Installation Information

 About ETERNUS Multipath Driver for Windows

ETERNUS Multipath Driver for Windows (hereafter referred to as "Multipath Driver") is based on Microsoft
Storage Technologies - MPIO framework. Multipath Driver is equivalent to Device Specific Module (DSM) in
MPIO framework.

 Supported Operation System (OS) Versions

This table shows the versions of Windows supported by Multipath Driver.

    Multipath Driver
   Supported OS Versions
    Version Level
   Microsoft® Windows Server® 2008 Standard
   Microsoft® Windows Server® 2008 Enterprise
   Microsoft® Windows Server® 2008 Datacenter    V2.0L14 or later
   Microsoft® Windows Server® 2008 for Itanium-Based Systems
   Microsoft® Windows HPC Server® 2008
   Microsoft® Windows Server® 2008 R2 Standard
   Microsoft® Windows Server® 2008 R2 Enterprise
   Microsoft® Windows Server® 2008 R2 Datacenter    V2.0L16 or later
   Microsoft® Windows Server® 2008 R2 for Itanium-Based Systems
   Microsoft® Windows HPC Server® 2008 R2
   Microsoft® Windows Server® 2012 Essentials
   Microsoft® Windows Server® 2012 Standard    V2.0L19 or later
   Microsoft® Windows Server® 2012 Datacenter
   Microsoft® Windows Server® 2012 R2 Essentials
   Microsoft® Windows Server® 2012 R2 Standard
    V2.0L20 or later
   Microsoft® Windows Server® 2012 R2 Datacenter
   Microsoft® Windows Storage Server® 2012 R2 Standard
   Microsoft® Windows Server® 2016 Essentials
   Microsoft® Windows Server® 2016 Standard    V2.0L23 or later
   Microsoft® Windows Server® 2016 Datacenter
   Microsoft® Windows Server® 2019 Essentials
   Microsoft® Windows Server® 2019 Standard    V2.0L24 or later
   Microsoft® Windows Server® 2019 Datacenter
   Microsoft® Windows Server® 2022 Essentials
   Microsoft® Windows Server® 2022 Standard    V2.0L25 or later
   Microsoft® Windows Server® 2022 Datacenter

  For Windows Server 2008
    The architecture types of x86 (32-bit), x64 and IA64 (Itanium) are supported.
    The software levels of SP1 (no SP applied) and SP2 are supported. SP2 is supported by V2.0L14 or later.

  For Windows Server 2008 R2
    The architecture types of x64 and IA64 (Itanium) are supported.
    The software levels of SP0 (no SP applied) and SP1 are supported. SP1 is supported by V2.0L16 or later.

  For Windows Server 2016
   Nano Server is not supported.

  For Windows Server 2019
   Nano Server is not supported.

  For Windows Server 2022
   Nano Server is not supported.

  Hyper-V are supported, see also Hyper-V environment.

    4

    ETERNUS Multipath Driver Installation Information

 Supported Storage Systems

Multipath Driver supports the following storage systems.
• ETERNUS DX60 S2
• ETERNUS DX80 S2
• ETERNUS DX90 S2
• ETERNUS DX60 S3
• ETERNUS DX60 S4
• ETERNUS DX60 S5
• ETERNUS DX100 S3
• ETERNUS DX100 S4
• ETERNUS DX100 S5
• ETERNUS DX200 S3
• ETERNUS DX200 S4
• ETERNUS DX200 S5
• ETERNUS DX200F
• ETERNUS AF150 S3
• ETERNUS AF250
• ETERNUS AF250 S2
• ETERNUS AF250 S3
• ETERNUS DX400 S2 series
• ETERNUS DX500 S3
• ETERNUS DX500 S4
• ETERNUS DX500 S5
• ETERNUS DX600 S3
• ETERNUS DX600 S4
• ETERNUS DX600 S5
• ETERNUS AF650
• ETERNUS AF650 S2
• ETERNUS AF650 S3
• ETERNUS DX900 S5
• ETERNUS DX8000 S2 series
• ETERNUS DX8000 S3 series
• ETERNUS DX8900 S4

 ETERNUS DX60 S2, ETERNUS DX80 S2, ETERNUS DX90 S2

    Storage System    Multipath Driver Product Names   Version Level

   ETERNUS DX60 S2    for Entry Model
   ETERNUS DX80 S2    for Standard Model    V2.0L18 or later
   ETERNUS DX90 S2    for Enterprise Model

 ETERNUS DX60 S3, ETERNUS DX100 S3, ETERNUS DX200 S3, ETERNUS DX200F, ETERNUS DX500
S3, ETERNUS DX600 S3

    Storage System    Multipath Driver Product Names   Version Level
   ETERNUS DX60 S3
    for Entry Model
   ETERNUS DX100 S3
    for Standard Model
   ETERNUS DX200 S3
    for Enterprise Model    V2.0L20 or later   ETERNUS DX200F
   ETERNUS DX500 S3    for Standard Model
   ETERNUS DX600 S3    for Enterprise Model

    5

    ETERNUS Multipath Driver Installation Information

 ETERNUS DX60 S4, ETERNUS DX100 S4, ETERNUS DX200 S4, ETERNUS DX500 S4, ETERNUS
DX600 S4

    Storage System    Multipath Driver Product Names   Version Level

   ETERNUS DX60 S4    for Entry Model
   ETERNUS DX100 S4    for Standard Model
   ETERNUS DX200 S4    for Enterprise Model
    V2.0L21 or later

   ETERNUS DX500 S4    for Standard Model
   ETERNUS DX600 S4    for Enterprise Model

 ETERNUS DX60 S5, ETERNUS DX100 S5, ETERNUS DX200 S5, ETERNUS DX500 S5, ETERNUS
DX600 S5

    Storage System    Multipath Driver Product Names   Version Level

   ETERNUS DX60 S5    for Entry Model
   ETERNUS DX100 S5    for Standard Model
   ETERNUS DX200 S5    for Enterprise Model
    V2.0L21 or later

   ETERNUS DX500 S5    for Standard Model
   ETERNUS DX600 S5    for Enterprise Model

 ETERNUS AF150 S3, ETERNUS AF250 S3/AF250 S2/AF250

   ETERNUS AF150 S3
    for Entry Model
   ETERNUS AF250 S3
    for Standard Model    V2.0L22 or later
   ETERNUS AF250 S2
    for Enterprise Model
   ETERNUS AF250

 ETERNUS AF650 S3/AF650 S2/AF650

    Storage System    Multipath Driver Product Names   Version Level
   ETERNUS AF650 S3
    for Standard Model
   ETERNUS AF650 S2    V2.0L22 or later
    for Enterprise Model
   ETERNUS AF650

 ETERNUS DX900 S5

    Storage System    Multipath Driver Product Names   Version Level

    for Standard Model
   ETERNUS DX900 S5    V2.0L22 or later
    for Enterprise Model

    6

    ETERNUS Multipath Driver Installation Information

ETERNUS DX400 S2 series

   Storage System    Multipath Driver Product Names   Version Level

    for Standard Model
  ETERNUS DX400 S2 series    V2.0L18 or later
    for Enterprise Model

ETERNUS DX8000 S2 series

   Storage System    Multipath Driver Product Names   Version Level

    for Standard Model
  ETERNUS DX8000 S2 series up to 2 Paths
    for Enterprise Model    V2.0L18 or later
  ETERNUS DX8000 S2 series    for Enterprise Model

ETERNUS DX8900 S4, ETERNUS DX8000 S3 series

   Storage System    Multipath Driver Product Names   Version Level
  ETERNUS DX8700 S3 up to 2 Paths
    for Standard Model
  ETERNUS DX8900 S3 up to 2 Paths
    for Enterprise Model
  ETERNUS DX8900 S4 up to 2 Paths
    V2.0L22 or later
  ETERNUS DX8700 S3
  ETERNUS DX8900 S3    for Enterprise Model
  ETERNUS DX8900 S4

    7

    ETERNUS Multipath Driver Installation Information

 Related Products Requirements

Supported Related Products are as follows:
For the combinations of servers, HBAs, and topologies, please contact us.

 Related Hardware Product Requirements

• FC card
   Server    HBAs    Multipath Driver Version Level
    PG-FC105    S26361-F2624-E1
    S26361-F2843-E1
    PG-FC106
    S26361-F2843-E201
    S26361-F3141-E10
    PG-FC107
    S26361-F3141-E210
    PG-FC201    S26361-F3141-E1
    S26361-F3306-E1
    PG-FC202(L)
    S26361-F3306-E201
    PG-FC203(L)    S26361-F3961-E1
    PY-FC201(L)    S26361-F3961-E201
    PG-FC204(L)    S26361-F3961-E2
    PY-FC202(L)    S26361-F3961-E202
    PG-FC205(L)    V2.0L10 or later
    S26361-F3631-L1
    PY-FC211(L)
    PG-FC206(L)
    S26361-F3631-L2
    PY-FC212(L)
    PY-FC221 (L)  PRIMERGY/
    PY-FC222 (L)  PRIMEQUEST
    S26361-F3023-E1
    PG-FCD101
    S26361-F3023-E2
    PG-FCD102
    S26361-F3023-L2
    S26361-F3306-E601
    PG-FCD201
    S26361-F3306-L601
    PG-FCD202
    MC-FC82E
    PY-FCD02
    PY-FCD12
    PY-FC311(L)    V2.0L20 or later
    PY-FC312(L)

    MC-08FCxx    V2.0L11 or later

    MC-0JFCxx    V2.0L16 or later

    MCX0JFCxx    V2.0L16 or later

    Emulex FC Cards
    V2.0L10 or later
   3rd party PC servers    Qlogic FC Cards
    Brocade FC Cards    V2.0L16 or later

    8

    ETERNUS Multipath Driver Installation Information

• SAS card
   Server    HBAs    Multipath Driver Version Level
    PG-228B(L)
    PY-SC1Y0(L)
    V2.0L14 or later
    PG-22DC(L)
    PY-SC2Z0
  PRIMERGY
    PY-SCD08    V2.0L19 or later
    PG-SAD201
    V2.0L20 or later
    PY-SC3FE

   3rd party PC servers    LSI Logic SAS Cards    V2.0L14 or later

• iSCSI
   Server    NICs    Multipath Driver Version Level
  PRIMERGY/
    S26361-F3011-E1 etc.
  PRIMEQUEST
    V2.0L12 or later
    Intel Pro/1000MT etc.
   3rd party PC servers
    Qlogic iSCSI Cards    V2.0L10 or later

• FCoE
   Server    CNAs    Multipath Driver Version Level
    PG-292B(L)    S26361-F3592-L2
    PY-CN202(L)    S26361-F3592-L202
    PG-CND201    MC-CNA102E-F    V2.0L16 or later
  PRIMERGY
    PY-CND02    MC-CNA112E-F

    PY-CN302    V2.0L18 or later

   3rd party PC servers    Emulex CNA Cards    V2.0L16 or later

• Topology
   Interface    Topology    Multipath Driver Version Level

    FC-AL
  FC    V2.0L10 or later
    Fabric

    Point-to-Point    V2.0L14 or later
  SAS
    Fabric (*1)    V2.0L18 or later

    Point-to-Point
   iSCSI    V2.0L10 or later
    Switch

  FCoE    Fabric    V2.0L16 or later

   *1: Only ETERNUS DX80 S2, DX90 S2, DX60 S3, DX100 S3 or DX200 S3.

    9

    ETERNUS Multipath Driver Installation Information

 Related Software Product Requirements

• Clustering Software
   Clustering Software    Multipath Driver Version Level

  SafeCLUSTER    V2.0L10 or later

  EXPRESSCLUSTER    V2.0L18 or later

   LifeKeeper    V2.0L18 or later

  WSFC (Windows Server 2008)    V2.0L14 or later

  WSFC (Windows Server 2008 R2)    V2.0L16 or later

  WSFC (Windows Server 2012)    V2.0L19 or later

  WSFC (Windows Server 2012 R2)    V2.0L20 or later

  WSFC (Windows Server 2016)    V2.0L23 or later

  WSFC (Windows Server 2019)    V2.0L24 or later

  WSFC (Windows Server 2022)    V2.0L25 or later

  WSFC: Windows Server Failover Cluster

• Microsoft iSCSI Software Initiator
   iSCSI Software Initiator Version    Multipath Driver Version Level

   Version 2.02 or later    V2.0L12 or later

• HBA Drivers
  HBA Drivers    Multipath Driver Version Level

   SCSIport Miniport Driver
    V2.0L10 or later
   Storport Miniport Driver (*2)

 Virtualization Environments

   Virtualization Environments    Running on Host OS     Running on Guest OS

  Hyper-V    Supported    Supported

  VMware    N/A    Not Supported

   Linux Xen    N/A    Not Supported

   Linux KVM    N/A    Not Supported

    10

    ETERNUS Multipath Driver Installation Information

 Hyper-V environment

Multipath Driver must be installed in the OS which see the multipath connections to the LUNs.

    Host OS    Host OS

    Guest OS: Virtual machine    Guest OS: Virtual machine

    Install in
    Guest OS.
    Multipath Driver

    Multipath Driver    Install in
    Host OS.    HBA/NIC   HBA/NIC

    HBA/NIC/CNA    HBA/NIC/CNA    HBA/NIC   HBA/NIC

    ETERNUS    ETERNUS
    Disk Storage System    Disk Storage System

    ETERNUS LUN is visible on the Host OS.    ETERNUS LUN is not visible on the Host OS.

    The figure above to the left is for a LUN on storage system that is recognized on Host
    OS. In a configuration like this, Multipath Driver must be installed in Host OS.

    The figure above to the right is for a LUN on storage system is not recognized on Host
    OS. The Guest OS directly recognizes the LUN on storage system without going
    through Host OS. For example, if you install MS iSCSI Initiator in Guest OS, the right
    figure is applied. Multipath Driver must be installed in the Guest OS.

     CAUTION
    -For the configuration shown above in the figure to the left, even if the LUN on the Host
    OS is configured to be seen by the Guest OS, Multipath Driver does not need to be
    installed in Guest OS.
    -The host interface which supports the configuration shown above in the figure to
    the right is iSCSI and Virtual Fibre Channel.
    -When use Virtual Fibre Channel,It is necessary to connect FC switch corresponding
    to NPIV.

The supported Host OS of Multipath Driver.
    ・Microsoft Windows Server 2012 Standard
    ・Microsoft Windows Server 2012 Datacenter
    ・Microsoft Windows Server 2012 R2 Standard
    ・Microsoft Windows Server 2012 R2 Datacenter
    ・Microsoft Windows Server 2016 Standard
    ・Microsoft Windows Server 2016 Datacenter
    ・Microsoft Windows Server 2019 Standard
    ・Microsoft Windows Server 2019 Datacenter
    ・Microsoft Windows Server 2022 Essentials
    ・Microsoft Windows Server 2022 Standard
    ・Microsoft Windows Server 2022 Datacenter

The supported Guest OS of Multipath Driver.
    ・Microsoft Windows Server 2012 Essentials
    ・Microsoft Windows Server 2012 Standard
    ・Microsoft Windows Server 2012 Datacenter

    11

    ETERNUS Multipath Driver Installation Information

・Microsoft Windows Server 2012 R2 Essentials
・Microsoft Windows Server 2012 R2 Standard
・Microsoft Windows Server 2012 R2 Datacenter
・Microsoft Windows Server 2016 Essentials
・Microsoft Windows Server 2016 Standard
・Microsoft Windows Server 2016 Datacenter
・Microsoft Windows Server 2019 Essentials
・Microsoft Windows Server 2019 Standard
・Microsoft Windows Server 2019 Datacenter
・Microsoft Windows Server 2022 Essentials
・Microsoft Windows Server 2022 Standard
・Microsoft Windows Server 2022 Datacenter

    12

    ETERNUS Multipath Driver Installation Information

 Channel Adapter ID and Connection Points

CAID is the information displayed on the Multipath Manager window and it can identify the location of the port in
the storage system.
CAID is different from a physical port number. To confirm a physical port number, refer to the manual of the
storage system. Please note that the port position and the physical port number depend on the type of storage
system.

 ETERNUS DX60 S2 rear view

    [FC / iSCSI]

    CM0CM0    CM1CM1
    0000    0101    0202    0303

    PSU0PSU0    PSU1PSU1

    CM:CM: ControllerController Module,Module, PSU:PSU: PowerPower SupplySupply UnitUnit
    :: WhenWhen usingusing 22 portport CMCM

    [SAS]

 ETERNUS DX60 S5, ETERNUS DX60 S4, ETERNUS DX60 S3 rear view

    CM0CM0    CM1CM1
    0000    0101    0202    0303

    PSU0PSU0    PSU1PSU1

    CM:CM: ControllerController Module,Module, PSU:PSU: PowerPower SupplySupply UnitUnit
    :: WhenWhen usingusing 22 portport CMCM

    13

    ETERNUS Multipath Driver Installation Information

 ETERNUS DX100 S5, ETERNUS DX100 S4, ETERNUS DX100 S3 rear view
When CA of FC is installed in the basic host interface

When CA other than FC are installed in the basic host interface

 ETERNUS DX200 S4, ETERNUS DX200 S3, ETERNUS DX200F, ETERNUS AF150 S3/AF250 S2/AF250,
ETERNUS DX80 S2, ETERNUS DX90 S2 rear view

    14

    ETERNUS Multipath Driver Installation Information

 ETERNUS DX200 S5, ETERNUS AF250 S3

 ETERNUS DX500 S5/DX500 S4/DX500 S3, ETERNUS DX600 S5/DX600 S4/DX600 S3, ETERNUS
AF650 S3/AF650 S2/AF650, ETERNUS DX8100 S3,ETERNUS DX400 S2 series rear view

    15

    ETERNUS Multipath Driver Installation Information

ETERNUS DX 900 S5 rear view

    16

    ETERNUS Multipath Driver Installation Information

ETERNUS DX8100 S2 rear view

ETERNUS DX8700 S2 front view

    17

    ETERNUS Multipath Driver Installation Information

ETERNUS DX8900 S4, ETERNUS DX8700 S3, ETERNUS DX8900 S3 rear view

    18

ETERNUS Multipath Driver Installation Information

    19

ETERNUS Multipath Driver Installation Information

    20

    ETERNUS Multipath Driver Installation Information

 Assigned-/ Non-assigned-CM Type Storage Systems

For ETERNUS, there are two system types: “Assigned-CM” and “Non-assigned-CM.”  With Assigned-CM
storage systems, the main access path for each LU is assigned to a particular controller. With Non-assigned-CM
storage system, there are no assigned LU access paths as such.

With “Assigned-CM” type storage systems, the path connected to the assigned controller is active. Paths to other
controllers are on standby. With “Non-assigned-CM” type storage systems, all paths are active and used for
access.

The table below shows the “Assigned-CM” and “Non-assigned-CM” storage systems.

Load balancing/fail over performance can differ depending on “Assigned-CM” and “Non-assigned-CM” use and
the number of paths employed. For details, refer to the supplied product manual.

    ETERNUS DX60 S2
    ETERNUS DX80 S2
    ETERNUS DX90 S2
    ETERNUS DX60 S3
    ETERNUS DX60 S4
    ETERNUS DX60 S5
    ETERNUS DX100 S3
    ETERNUS DX100 S4
    ETERNUS DX100 S5
    ETERNUS DX200 S3
    ETERNUS DX200 S4
    ETERNUS DX200 S5
    ETERNUS DX200F
    ETERNUS AF150 S3
   Assigned-CM type
    ETERNUS AF250
    ETERNUS AF250 S2
    ETERNUS AF250 S3
    ETERNUS DX400 S2 series
    ETERNUS DX500 S3
    ETERNUS DX500 S4
    ETERNUS DX500 S5
    ETERNUS DX600 S3
    ETERNUS DX600 S4
    ETERNUS DX600 S5
    ETERNUS AF650
    ETERNUS AF650 S2
    ETERNUS AF650 S3
    ETERNUS DX8100 S3

    ETERNUS DX900 S5
    ETERNUS DX8000 S2 series
   Non-assigned-CM type    ETERNUS DX8700 S3
    ETERNUS DX8900 S3
    ETERNUS DX8900 S4

    21

    ETERNUS Multipath Driver Installation Information

Notes

1. LUN mapping
    If LUN mapping in the storage system is not set properly, Windows may not recognize LUNs correctly.
   For proper LUN mapping, the LUN numbers Windows recognizes must be in ascending order from
   LUN 0.
2. HBA driver settings
    If the HBA driver settings are not correct, Windows may not recognize LUNs correctly. For proper HBA
    driver settings, follow the instructions written in the “Disk Storage System Server Connection Guide” or
   “User Guide – Server Setting Guide” that comes with the storage system.

    22

    ETERNUS Multipath Driver Installation Information

Multipath Driver Updates

 The following table shows the updates for each Multipath Driver version:

  Version No.    Detail
    First edition
 V2.0L10    - Added Microsoft MPIO framework
   (Jan / 2005)    - Added support for iSCSI
    - Added support for Storport Miniport
  V2.0L11    - Added support for Windows Server 2003 x64
   (Jul / 2005)    - Included the GR Multipath Driver V1.0L14
    - Added support for the ETERNUS4000 and ETERNUS8000
    - Added support for the QLogic Storport Miniport driver
 V2.0L12    - Added support for load balancing in the MSCS environment
   (Jun / 2006)    (added a function to convert SCSI2 Reserve to Persistent Reserve)
    - Added a function to collect an event log for the following sense information:
    06/fb80 (Sense key = 0x06, ASC = 0xfb, ASCQ = 0x80)
 V2.0L13
    - Added support for the ETERNUS2000
  (Aug / 2007)
    - Added support for Windows Server 2008
 V2.0L14    - Added support for SAS
   (Apr / 2008)    - Added event log ID=305
    (detection of no controller redundancy in the storage system)

    - Added support for the ETERNUS DX series
 V2.0L15
    - Discontinued the client version package that was included in the product
   (Jun / 2009)
    - Discontinued the HTML version user’s guide
    - Added support for Windows Server 2008 R2
 V2.0L16    - Improved the path switching process when path failures occur
   (Oct / 2009)    - Added a function to collect an event log for the following sense information:
    06/fb8x (Sense key = 0x06, ASC = 0xfb, ASCQ = 0x8x)
    - Added a function to set timeout information of the Emulex Storport Miniport driver
    - Added a function to monitor I/O response time
    - Added a function to monitor the recurrence of path reconnection errors
    - Added a function to scan devices
 V2.0L17    - Added the following event logs
   (Oct / 2010)    ID=203, 204, 306, 308, 310, 311, 1014, 2000, 2002, 2004, 2012, 2022, 2032,2100
    - Changed some parts of character strings that are displayed in the description
    column of the following event logs:
    ID=201, 202, 301, 304, 305, 401, 402, 403, 1010, 1020, 1030, 1040, 1050,1051,
    1100, 1200

 V2.0L18    - Added support for the ETERNUS DX80 S2, DX90 S2, and DX400 S2 series.
   (June / 2011)    - Added the function the warning status remains for six minutes.

 V2.0L19
    - Added support for Windows Server 2012
  (Nov / 2012)

    - Added support for the TPG Referrals function. For details, refer to "ETERNUS Web
    GUI User's Guide ETERNUS DX80 S2/DX90 S2, ETERNUS DX410 S2/DX440 S2,
    ETERNUS DX8100 S2/DX8700 S2" (tenth edition or later)
 V2.0L20
    - Added a function to set timeout information to the Emulex Storport Miniport driver
   (Jul / 2013)
    that has the file name elxfc.sys
    - Added the following event logs:
    ID=312 and 313
 V2.0L21
    - Added support for the Storage Cluster function.
   (Jul / 2014)

    23

    ETERNUS Multipath Driver Installation Information

Version No.    Detail
V2.0L22
    - Added support for the ETERNUS DX8700 S3/DX8900 S3.
 (Jul / 2015)
V2.0L23
    - Added support for Windows Server 2016
 (Dec / 2016)
V2.0L24
    - Added support for Windows Server 2019
 (Jan / 2019)
V2.0L25
    - Added support for Windows Server 2022
 (Jan / 2022)

    24

    ETERNUS Multipath Driver Installation Information

About This Document
This document is devoted to providing technical information. The contents of this document may be modified without any prior notice.
Please contact FUJITSU LIMITED if you find any error in descriptions.

FUJITSU LIMITED is not responsible for indemnity that might be caused by the contents in this documentation or any damage related to
contents in this documentation.

FUJITSU LIMITED
http://www.fujitsu.com/storage/

    25
3 次浏览 更新于 2026-11-04

同组文章Fujitsu

查看本组全部 2 篇

没有找到想要的答案?

上传日志让 AI 帮你诊断,或者在控制台里直接向 AI 提问。