更换 RAID 卡后导入 Foreign 配置(MSM)

Importing Foreign Configuration after Raid Adapter has been replaced

Environment

  1. IBM X Series Servers
  2. IBM ServeRAID-MR10K SAS/SATA Controller

Cause

After Replacing the Raid Adapter on IBM X Series, Server may report Foreign Configuration message

Resolution

1) Power on the Server
更换 RAID 卡后导入 Foreign 配置(MSM)
、
2) During Post Message will be displayed about Foreign Configuration. Press any key or {C} to load the configuration Utility.
3) Additional Warning message is displayed, Press {Y} to confirm
In this case Server just has one Raid Adapter installed, ie- IBM ServerRAID-MR10K, If multiple Raid adapters are installed the same will be listed, as below. Click Start to Continue.
更换 RAID 卡后导入 Foreign 配置(MSM)

4) In this case the Adapter has found a single Foreign Configuration, DO NOT CLEAR THE CONFIGURATION.
Click on Preview to View the configuration
更换 RAID 卡后导入 Foreign 配置(MSM)

Here we have we have 4 SAS Hard Drives and 1 Virtual Disk –VD0- Raid Level 0 Configured
更换 RAID 卡后导入 Foreign 配置(MSM)

5) Select Import to save the configuration.
更换 RAID 卡后导入 Foreign 配置(MSM)

6) Configuration has been imported, Return to Main Web Bios Menu Options.
更换 RAID 卡后导入 Foreign 配置(MSM)