MegaCLI 常用命令速查
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL 【查raid级别】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL 【查raid卡信息】
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL 查看【硬盘信息】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll 【查看电池信息】
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL 【查看raid卡日志】
/opt/MegaRAID/MegaCli/MegaCli64 -adpCount 【显示适配器个数】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpGetTime –aALL 【显示适配器时间】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aAll 【显示所有适配器信息】
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll 【显示所有的物理信息】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】
/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】
Check
/opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALLww
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -CfgDsply -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -EncInfo -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL
MegaCli Commands:Replace
MegaCli -PDList -a0
MegaCli -PDOffline -PhysDrv[252:3] -a0
MegaCli -PDMarkMissing -PhysDrv [252:3] -a0
MegaCli -PDPrpRmv -PhysDrv [252:3] -a0
MegaCli -PDHSP -Set -PhysDrv[252:3] -a0
MegaCli -PDRbld -ShowProg -PhysDrv[252:3] -a0In case you’re not working with hot spares, you must re-add the new drive to your RAID virtual drive and start the rebuilding
MegaCli -PdReplaceMissing -PhysDrv[252:3] -Array0 -row0 -a0
MegaCli -PDRbld -Start -PhysDrv[252:3] -a0
MegaCli -PDRbld -ShowProg -PhysDrv[252:3] -a0How to Rebuild a Drive That is Marked as "Foreign" When Inserted:
MegaCli -PDMakeGood -PhysDrv[252:5] -a0
MegaCli -CfgForeign -Clear -aALL
MegaCli -PDHSP -Set -PhysDrv[252:6] -a0/opt/MegaRAID/MegaCli/MegaCli -PDMakeGood -PhysDrv[64:2] -force -a0
/opt/MegaRAID/MegaCli/MegaCli -PDHSP -Set -PhysDrv[64:2] -a0
/opt/MegaRAID/MegaCli/MegaCli -PDRbld -ShowProg -PhysDrv[64:0] -a0